3. Specifications
LOOP Resistance
L- PE (Hi-Amp)
Range (Ω)
0.23 – 9.99
10.0 – 99.9
100 – 999
Measuring Current ........................................................................... 8.0 A ~ 25 A
Range of the Voltage Used ........................................195V AC – 260V AC (50,60Hz)
L- PE (No Trip)
Range (Ω)
0.23 – 9.99
10.0 – 99.9
100 – 999
Measuring Current .......................................................................... < 15mA
Range of the Voltage Used .................................195V AC– 260V AC (50,60Hz)
LINE Resistance
L- N
Range (Ω)
0.23 – 9.99
10.0 – 99.9
100 – 999
Measuring Current ......................................................................... 4.0 A
Range of the Voltage Used .............................195V AC – 260V AC (50,60Hz)
RCD (EN 61557-6)
) ............................................10mA, 30mA, 100mA, 300mA, 500mA and 1A.
Rcd Rating (I
n
Test current ...............................................x1/2, x1, x2 and x5
Resolution(Ω)
0.01
0.1
1
Resolution(Ω)
0.01
0.1
1
Resolution(Ω)
0.01
0.1
1
Accuracy
±(4% of reading+ 6digits)
Accuracy
±(5% of reading+ 6 digits)
Accuracy
±(4% of reading+ 6digits)