Herunterladen Inhalt Inhalt Diese Seite drucken

Cleaning Of The Frequency Regulator (Option); Cleaning Of The Water Filters; Maintenance At Expense Dibo Technicians - Dibo 2D MPU-M Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6.2.5. Cleaning of the frequency regulator (option)

Clean the frequency regulator periodically on dust phenomena and clean the cooling element, regularly
check the span couples of the end poles.
Annually (in case of storage) charge the capacitors (see attached manual of frequency regulator).
Once a year / 2 year (depending on environment):
- Check the input and output end poles and I / O terminals.
- Clean the cooling tunnel
- Check operation of cooling fan
- Check for corrosion of terminal poles, power lines and other surfaces
- Check filters in case of cabinet installation
Once every 5 to 7 years: replace cooling fans
Once every five to 10 years: replace DC- bus capacitors.

6.2.6. Cleaning of the water filters

Clean the water filters regular and remove possible dirt.

6.2.7. Maintenance at expense DiBO technicians

For further maintenance (burner, engines, high pressure pump and parts who has to do with safety) we
advise to contact your DiBO distributor concerning a maintenance contract. The maintenance applies to
normal company circumstances. At heavy circumstances you can communicate this so that can be taken
into account.
Supplement documents:
Control manual
CE- certificate
Remarks:
We advise the owner/user at strongest to make an appointment with DiBO against reaching the given up
company hours, to be able to guarantee a good and regular maintenance concerning a maintenance turn.
DiBO b.v. 59

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis