Herunterladen Inhalt Inhalt Diese Seite drucken

Preselection - Infraworld Saunacontrol C Montage- Und Gebrauchsanweisungen

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Preselection may only be used with a cover protection system for the heater or door contact switch.
Press the
-button in standby mode and the start screen will appear.
Hold the
button for longer (2 sec.), the display shows "prog. pre-select OFF", with the
-
change to "prog. pre-select ON".
By pressing the
-button again, the adjustable features will be shown on the display one after the other:
1. "start - time" (selection only possible for the next 24 hours)
2. "operat. type" (preselection of desired operating mode: sauna)
3. Set "current time"
4. "max. oper. time" to be adjusted from 30 minutes to 20 hours
Set max. 6 hours in private operation, max. 12 hours in commercial operation according to
STANDARD EN60335-2.
By pressing the
-button once more, the controls change to the "pre-select active" mode.
The sauna controls are now in the "pre-select active" mode and switch on according to the adjusted time and
operating mode.
The pre-selected starting time can only be set within the next 24 hours.
The "pre-select active" mode is switched off again by pressing the
disconnecting rocker is activated, preselection is deactivated (according to STANDARD EN60335-2 - Telecontrol).
8. PRESELECTION MODE
-button. When the door contact switch or
-button you can
EN
29

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

B6749

Inhaltsverzeichnis