Herunterladen Inhalt Inhalt Diese Seite drucken

Connection For Measuring The Line Temperature; Air-Conditioning And Refrigeration Connection - Wohler Smart Connect SC 660 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

8

Connection for measuring the line temperature

Fig. 12: Measuring the line temperature
9

Air-conditioning and refrigeration connection

Fig. 13: Connection valve (art. no.
62694) connected to measuring socket
Connection for measuring the line temperature
The connection valve ensures that the refrigerant
loss during the measurement is as low as possible.
Example
Measuring socket
Refrigeration system
To measure the line temperature, connect the
clamp temperature sensors to the underside of
the Wöhler SC 660, see Fig. 3, No. 1.
For pressure measurement on refrigeration
systems use the Wöhler connection valve Art.
No. 62694.
NOTE!
Screw the connection valve onto the measur-
ing socket.
EN