Fig. 8: Pre-settings pressure test on
water pipes with water
Fig. 9: Display of the pressure curve
during the measurement
Pressure tests on water pipes
Connect a temperature measuring clamp to
the Wöhler SC 660 and measure the tempera-
ture of the water pipe.
Tap on the temperature value "Media temper-
ature" in the app and then enter the measured
temperature as the media temperature in the
app.
Tap on the blue field "Ambient temperature" to
accept the measured temperature value or tap
on the field of the temperature value to enter
it.
Enter the desired test pressure, stabilization
time and measurement time if you want to
change the pre-set values.
Tap the icon for zeroing the pressure if you
want to zero the pressure sensor.
Tap on "Start measurement".
Apply the desired test pressure to the water
pipe.
The stabilisation phase follows.
After the stabilisation phase, the measurement
starts automatically. During the measurement,
the pressure curve can be followed in a graph.