it. Do not drag pans or plates over the sur-
face.
Cabinet requirements
Installation
• The appliance is intended for recessed in-
stallation in the kitchen worktop above a
cabinet with a width of 600 mm or more.
• If the appliance is installed on flammable
materials, it is necessary to strictly comply
with the guidelines and regulations regard-
ing low voltage installations and fire pro-
tection.
• For fitted units, the components (plastic
materials and veneered wood) must be as-
sembled with heat-resistant adhesives
(min. 85 °C): Unsuitable materials and ad-
hesives can result in warping and detach-
ment.
• The kitchen cabinet must allow sufficient
room for the electrical connections of the
appliance. Suspended kitchen cabinets
above the appliance must be installed at a
distance that provides enough room for
comfortable working process.
• The use of hard wood decorative borders
around the worktop behind the appliance
is allowed, in this case the minimum dis-
tance remains as indicated on the installa-
tion illustrations.
• Positioning and dimensions of the cut-out
for built-in appliance is shown in the illus-
tration below. The measurements shown
are only valid if the following condition is
met: worktop overhang to cabinet front is
35 mm.
• Minimum distance between built-in appli-
ance and any cabinet above is 500mm.
+2
560
mm
+2
490
555 mm
18 - 40mm
mm
• To prevent leakage of liquid between the
edge of the hob and the worktop, place the
adhesive seal provided along the entire
outer edge of the hob before assembly.
Please refer to Assembly Instruction.
Please refer to the assembly instructions.
Electrical connection
• All electrical connections must be carried
out by an authorised installer.
• Follow the connection diagram (on the un-
der side of the product).
• This appliance has a Y-type connection and
requires a mains cable H05VV-F. Cable
needs mandatory sleeves. According to IEC
regulations use for one-phase connection:
mains cable 3 x 4 mm², for two-phase con-
nection: mains cable 4 x 2.5 mm² and for NL
connection mains cable 5 x 2.5 mm². Ex-
ternal cable diameter: min 8 mm - max 12
mm. Please respect specific national regu-
lations in the first priority.
• The connection terminals can be accessed
by removing the junction box cover.
• Check that the domestic power supply
characteristics (voltage, maximum power
and current) are compatible with those of
the appliance.
• Connect the appliance as shown in the dia-
gram (in compliance with reference stand-
ards in force nationally for mains voltage).
• Do not weld any of the cables!
Min. 500 mm
9