Herunterladen Inhalt Inhalt Diese Seite drucken

hanseatic PREMIUM LINE VCB46A15F-70 Gebrauchsanleitung Seite 61

Bodenstaubsauger
Vorschau ausblenden Andere Handbücher für PREMIUM LINE VCB46A15F-70:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Problem
Appliance
switches itself
off.
Suction force is
weak.
Troubleshooting table
Possible cause
Brush/nozzle
blocked.
Motor protection
filter is blocked.
Overheat protection
has been activated.
Telescopic tube
/ suction hose is
blocked.
Dust bag is
not positioned
correctly.
Dust bag is full.
Brush / nozzle
is not positioned
correctly.
Object is plugging
the nozzle.
Filters are inserted
incorrectly or are
dirty.
Air by-pass vent is
open.
Solutions, tips
Actuate On/Off foot switch, pull
out mains plug, clean brush/
nozzle.
Actuate On/Off foot switch, pull
out mains plug, leave appliance
to cool for at least 1/2 hour and
clean motor protection filter.
Actuate On/Off foot switch,
pull out mains plug, check
telescopic tube and suction
hose for blockage, and clean if
necessary.
Insert the dust bag correctly.
Change the dust bag.
Position the brush / nozzle
correctly.
Actuate On/Off foot switch,
pull out mains plug, check
telescopic tube and suction
hose for blockage. Remove
object.
Insert filters correctly and/or
clean.
Close the air by-pass vent.