12.
b) Start a tool length measurement in UCCNC by
using the TLS button:
13. Now set the workpiece zero point for the Z-axis using the button:
UCCNC:
WinPC-NC:
The visual protection brush must touch the workpiece material during operation to avoid scattered
radiation.
14. Deactivate the integrated zero point sensor by moving
the switch to the upper position again. It is important to
check if the brushes touch the surface! Should this not
be the case, move the Z-axis accordingly and set the new
workpiece Z-axis zero point.
15. Start the program. The laser tool begins to work
and the operating LED turns on (picture is only
representation!). The machine moves around the pro-
grammed 40 x 40 mm square. After finishing the job, the
laser turns off (operating LED off).