The following must be checked during maintenance work:
the firm seating of the clamped electric lines
cracks in plastic enclosures
damage to the seals
damage to the luminaire cover
replace lamps?
cable gland(s) correct and tight
check lamp holders for colour change - replace if present
check lamp holders for stiffness - replace if present
check cables for damage - replace if present
Danger due to defective luminaire
Risk of severe or fatal injuries!
Take the luminaire out of operation if it is damaged.
Repair damage before recommissioning.
11.2 Maintenance
Cleaning must be carried out using only a moist cloth.
X
When cleaning with a damp cloth use water or mild, non-abrasive, non-scratching
X
cleaning agents.
Never use aggressive cleaning agents or solvents.
X
The light fitting is labeled with the note "Clean only with a damp cloth".
11.3 Repair
Replacing the luminaire cover
180°
Open the luminaire.
Swivel the lighting trough backwards by 180°.
Lift the lighting trough to detach it from the hinge.
Insert new lighting trough into the hinge.
All hinges must engage properly.
Close the luminaire.
Observe safety notes!
When replacing further spare parts, observe the documentation attached.