Technical data
Luminous Characteristics
Measures for light
guidance
Ambient conditions
Operating temperature
range
Mechanical data
Degree of protection
Protection class
Material
Enclosure
Enclosure
Colour
Gasket
Lamp cover
Lamp locking
Mounting / installation
Cable glands
Connection
222203 / 600160300010
2013-05-21·BA00·III·en·00
Standard:
Deep bowl, reflector of the lamp is white
Lateral dazzle limitation in the lamp cover
Through wiring
Type
without
6001/52.-...0-....
-30 °C ... 60 °C
6001/52.-...1-....
-30 °C ... 60 °C
6001/52.-...2-....
-30 °C ... 45 °C
6001/52.-...3-....
-30 °C ... 45 °C
6001/54.-...0-....
-30 °C ... 55 °C
6001/54.-...1-....
-30 °C ... 55 °C
6001/54.-...2-....
-30 °C ... 45 °C
6001/54.-...3-....
-30 °C ... 45 °C
6001/56.-...0-....
-20 °C ... 55 °C
6001/56.-...1-....
-20 °C ... 55 °C
6001/53.-...6-....
-30 °C ... 40 °C
6001/55.-...6-....
-30 °C ... 40 °C
6001/57.-...6-....
-30 °C ... 40 °C
The lowest ambient temperature when used with breather is -20 °C.
IP66 (IEC 60529)
I (with internal PE connection)
Polyester resin, glass fibre-reinforced
Colour white, similar to RAL 9010
colour grey, similar to RAL 7035
Silicone foam gasket in the lamp cover
Polycarbonate
Central locking which can be opened/closed using a socket key M8 / wrench size 13, hinged lamp
cover
Standard luminaire
Plastic:
1 x M25 x 1.5 cable gland 8161 and
2 x M25 x 1.5 stopping plugs 8290 (enclosed)
Metal:
2 x metal plates M20 x 1.5 connected by means of PE for metal cable entries
Attention: cable entries must be ordered separately
Special:
max. 4 bores for M20, M25, NPT ½''
max. 2 bores for NPT ¾''
Metal cable glands:
Standard:
Spring clamp terminals
5-pole: L1, L2, L3, N, PE
Clamping range: 1x 0.75 ... 4 mm
(2 free clamping units for each pole available)
Special:
Terminal block with covering
5-pole: L1, L2, L3, N, PE
Clamping range: 2x 0.75 ... 6 mm
with
-30 °C ... 50 °C
-30 °C ... 50 °C
-30 °C ... 40 °C
-30 °C ... 40 °C
-30 °C ... 50 °C
-30 °C ... 50 °C
-30 °C ... 40 °C
-30 °C ... 40 °C
-20 °C ... 50 °C
-20 °C ... 50 °C
-30 °C ... 40 °C
-30 °C ... 40 °C
-30 °C ... 40 °C
M20 x 1.5, M25 x 1.5; earthing of the metal cable
entries by means of metal plates
2
(solid / finely stranded)
2
(solid); 2x 0.75 ... 4 mm
Light Fittings for Fluorescent Lamps
Series EXLUX 6001
Technical data
2
(finely stranded)
7