Technical data
Technical data
Electrical data
Ballast
Power factor cos p
Disconnection of the light
End of life switch
6
Light Fittings for Fluorescent Lamps
Series EXLUX 6001
6001/...-...0-....
Lamp start
Cold start
Voltage
220 ... 240 Vac
Voltage
198 ... 264 Vdc
DC during switching
on
Voltage
176 ... 264 Vdc
DC during operation
Frequency
0 / 50 ... 60 Hz
Operation of the
1 lamp
lamps DC
Lamp standard
IEC 60081
Lamp power
18, 36, 58 W
Nominal current
1x18W 85mA
2x18W 170mA
1x36W 160mA
2x36W 320mA
1x58W 250mA
2x58W 500mA
6001/...-...2-....
Lamp start
Cold start
Voltage
110 ... 240 Vac
Voltage
104 ... 264 Vdc
DC during switching
on
Voltage
104 ... 264 Vdc
DC during operation
Frequency
0 / 50 ... 60 Hz
Operation of the
1 lamp
lamps DC
Lamp standard
IEC 60081
Lamp power
18, 36 W
Nominal current
1x18W 85 ... 175mA
2x18W 170 ... 345mA
1x36W 155 ... 330mA
2x36W 310 ... 660mA
cos p ) 0.97 capacitive; no additional compensation required
When opening the light
Switch with safety lock; when opening the central lock, all poles of the voltage supply to the ballast
are disconnected; contacts of the switching element are NC contacts, they can only be switched
on again when the lamp cover and the central locking system are closed.
In case of a lamp fault, the electronic ballast disconnects the defective lamp from the power
supply.
The electronic ballast, type 6042/9..-. fulfills the requirements according to IEC 61347-2-3
(simulation of the "end of life effect" of fluorescent lamps, "asymmetric pulse test 1" and
"asymmetric power test 2" correspond to the test conditions in the draft IEC 60079-7 ed.4
appendix H).
6001/...-...1-....
Cold start
220 ... 240 Vac
104 ... 264 Vdc
198 ... 264 Vdc
0 / 50 ... 60 Hz
2 lamps
IEC 60081
18, 36, 58 W
1x18W 85mA
2x18W 170mA
1x36W 160mA
2x36W 320mA
1x58W 250mA
2x58W 500mA
6001/...-...3-....
6001/...-...6-....
Cold start
Cold start
110 ... 240 Vac
120 ... 277 Vac
104 ... 264 Vdc
113 ... 294 Vdc
104 ... 264 Vdc
113 ... 294 Vdc
0 / 50 ... 60 Hz
0 / 50 ... 60 Hz
2 lamps
2 lamps
IEC 60081
ANSI C78.81
18, 36 W
17, 32, 40 W
1x18W 85 ... 175mA
1x17W 80...155mA
2x18W 170 ... 345mA
2x17W 160...305mA
1x36W 155 ... 330mA
1x32W 135...285mA
2x36W 310 ... 660mA
2x32W 270...570mA
1x40W 160...360mA
2x40W 325...715mA
222203 / 600160300010