Herunterladen Inhalt Inhalt Diese Seite drucken

Electric Connections - Camille Bauer KINAX N720-INOX Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

6. Mounting
All inclination transmitter can be mounted either directly
with 3 clamping brackets to the item being measured or with
a mounting plate with 4 cheese head screws M6. Please take
care that the installation position of the inclination transmitter
is perpendicular to the gravity of the earth. The inclination
transmitter are supplied standard with mounting plate but
without cheese head screws M6.
Mounting versions

7. Electric connections

The inclination sensor is connected via a highly fl exible,
shielded control lead with 4 strands. The same is preassem-
bled at the factory, included in the delivery and available in
different lenghts.
Permissible cable-Ø:
conductor cross-section:
wiring connection
N
μC
S
PSU
+
wt
8...33V DC
6.2 mm [0.244]
4 x 0.25 mm
2
-
br
gn
ye
Load resistor
4...20mA
• Avoid impacts or shocks on the hou-
sing.
• Do not deform housing.
• Do not open or mechanically modify the
device.
Drilling aund cut-out diagrams (for mounting transmitters)
Ø66,2
[2.606]
60,1
2.366
• Do not electricly modify the device nor
carry out any wiring work when energised.
• Do not plug in or unplug electric connection
when energised.
White (wt) = +24V
Brown (br) = 4...20 mA
Green (gn) = 100%
Yellow (ye) = 0%
M6
13

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis