The shutter
quenching cannot
be moved (is stuck)
when the burner is
in hot/cold
situation
Some fuel is spilt,
what should be
done before igniting
the burner again?
The flame is
unusually intense
and high
The burner does not
function properly
Environmental Management – End of Life circle
Beyond its life endurance, the device must not be rejected to the common domestic waste bins.
It must be recycled according to the Legislation standards for you country.
The care of each one of us for the environment guarantees better living conditions for our children
A. Τhe shutter quenching is dirty or
contains burn remains.
B. There is something that prevents
the shutter e.g. something come on to the
burner.
C. The burner has malfunction (e.g.
has suffered fall from height and is crooked).
D. The shutter has dilated
(temporarily due to heating from
extensive use)
It is possible to have been provoked by a strong air
current that blows towards the flame.
▪ Clean the burner and check if the
movement of the quenching shutter is
impeded by obstacles.
▪ Let it get cold.
▪ If no damage exists contact your
supplier. Do not use the burner again
before it has been maintained.
▪ Remove all the flammable sources.
▪ Remove people and animals from the
area.
▪ Wipe the spilled liquid using a dry
absorbent cloth, and afterwards, wipe
the same surface with a cloth soaked of
water.
▪ Αvoid inhaling the steam.
▪ Refresh the air in the room opening the
windows and the doors.
▪ Turn on the burner ONLY when the
room is refreshed and make sure that all
the spilled fuel has been wiped up.
Attention: Go to the (MSDS) of the fuel
for further information about the safe
handling of the fuel.
▪ Find and remove the source of the air
(probably the window/door is open.)
▪ If you cannot remove the source of the
air and the flame is too vivid, turn off
the burner.
▪ Maybe you should redefine the burner's
position to minimize the effect from the
air current.
▪ Contact the manufacturer/supplier for
assistance if the problem remains.
▪ Contact the manufacturer/supplier for
assistance
▪ Do not try to operate the burner when
malfunction occurs.