Minimum Dimensions of operation room
The ethanol fireplaces consume oxygen quantities during their function (ethanol burn).
It is necessary to replace the oxygen (ventilation of the room).
On table 1 the minimum space dimensions are mentioned (medium height 3 meters). For the calculation of the minimum
dimensions were consider as accepted the following:
▪ The space is a common house with average insulation where air flow is provided through its openings (doors etc).
▪ As minimum limit the 5,7m3 of provided air are taken for every 1000 BTU
BIO BURN TYPE
BIO 70
BIO 99
Safe Use Instructions
Before using the ethanol burner for the first time, make sure of the following:
▪ Remove all the packaging material, stickers and labels.
▪ Check the content of the packaging for any possible damage and make sure that all the parts are enclosed. Do not
use the burner if you realize any damage at the given parts.
▪ Make sure that you keep away all the packaging material from children. There is danger of accident or swallowing
parts.
Filling the burner with fuel
▪ To fill the burner with fuel, firstly you always draw the shutter to its closed position and then open the special filling
hole.
ATTENTION: Never fill the burner from its main opening because there might be small hearths , non-visible.
▪ Always fill the burner using the funnel to control the filling (e.g. funnel - See the Photo 4&5 - Page 7)
▪ Do not spill fuel out of the hole of the burner, there is serious danger of combustion. In case that fuel is spilt, wipe
carefully all the surfaces.
ATTENTION: Τhe fuel can destroy some surfaces (as wood, paint or skin).
▪ The burner is completely filled when the level of the fuel, during the filling, has reached the Max. mark. (The filling is done
in 2 steps. During the first filling, as soon as the fuel has reached the Max. mark, stop for 10-15'', letting it absorb a part of
the existent fuel. By the passage of the 10-15'', when the fuel level has been a little lessened, repeat the same procedure till
the fuel level reaches again the Max. mark.
Now the burner is completely filled.
▪ The burner doesn't require the maximum fill with fuel for the correct function but works better when it is full.
▪ Especially for the first use the burner must be filled completely and slowly.
▪ Do not store the fuel close to the burner. Use safety distance, one meter at least.
▪ Use only Bioethanol fuel. Fuels of different type are forbidden and constitute threat if used with burner of this type.
ATTENTION: Do not smoke during filling the burner with fuel and for as long as you handle the fuel.
Ignition
The burner is ready for ignition after having been filled with fuel.
▪ Draw the shutter to the open position.
▪ Use a suitable long lighter for the ignition of the burner's surface.
▪ Do not put your hands on the surface of the fuel and do not stand over the burner while you turn it on. The ignition
of the burner must be done from the side and no parts of the body or flammable material should be over it.
▪ Do not blow towards the burner during the ignition there is danger that flames can cause burn injury.
▪ The burner does not produce the highest flame from the beginning. The highest flame result (temperature and flame
height) comes after 10-15 minutes of operation.
DIMENSIONS
FUEL CAPACITY
(cm) (LxWxH)
71 Χ 26 Χ 8,3
100 Χ 29 Χ 8,3
NET
WEIGHT
(L)
(Kg)
3L
19.50
4L
30.00
3
ΑUTONOM
MINIMUM ROOM
Y (h)
DIMENSIONS (m3)
4.0
4.5
44
70

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Bio 99

Inhaltsverzeichnis