No�
Fault
Segments of the clamping
4
jaws do not separate widely
enough
Connector wobbles despite
5
a correct connection to the
test piece
6
Clamping jaws deformed
7
Clamping jaws do not close
If you should encounter any other problems, please contact WEH or your responsible distributor.
Can be recognized by
Possible cause
Wear
Connector is seated too
loosely, it sits unsteadily
on the test piece
Connector is not
correctly connected
Wear on geometry of the
test piece's connection
Incorrect connection
parts
geometry at test piece
Wear on the connector's
clamping jaws
Excessive mechanical
The sliding sleeve can
stress due to
no longer be connected
inappropriate handling
The sliding sleeve can
Wrong test piece
no longer be connected
Remedial measures
First check the test piece. If this is
defective, replace the test piece. If it is
in good condition, send the
connector to WEH for maintenance
Repeat the connecting procedure
Replace test piece
Return the connector to WEH
for maintenance
Return the connector to WEH
for maintenance
Use correct test piece