Herunterladen Inhalt Inhalt Diese Seite drucken

Alarm Letter Codes And Descriptions - Siemens SITRANS FUH1010 Betriebsanleitung (Kompakt

Vorschau ausblenden Andere Handbücher für SITRANS FUH1010:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

4.2

Alarm Letter Codes and Descriptions

Letter Code
S
Spacing
0
ZeroMatic
E
Empty
R
F
A
Aeration
M
Memory
K
Makeup
I
Interface
P
The display shown below indicates where the Alarm Codes appear on the LCD display
screen.
SITRANS FUH1010 Quick Start
Operating Instructions (Compact), 12/2008, CQO:QSG010 Revision A
All manuals and user guides at all-guides.com
Alarm
Transducer spacing may need readjustment.
ZeroMatic signal fault.
Pipe is empty.
Rate
Flow above High setting or below Low setting.
Fault
Three continuous seconds without new data update.
Current aeration percentage exceeds the alarm set point.
Last valid reading for a selected interval during Fault condition.
In-Process Makeup occurred.
Liquid Vs exceeds interface alarm set point.
Pig
Pig passage detected (optional).
Alarm Codes
Troubleshooting/FAQs
4.2 Alarm Letter Codes and Descriptions
Description
37

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

7me3601-4

Inhaltsverzeichnis