Herunterladen Inhalt Inhalt Diese Seite drucken

Check - OHAUS Defender 6000 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für Defender 6000:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

Defender 6000 Indicators
Yes button to clear the stored data and return to current mode.
Notes:
The item must be removed from the pan before the next item can be accumulated.
Only stable weights are stored.
Changing modes will clear the stored accumulation data.
When Legal for Trade is turned ON, for NTEP, gross and net weight cannot be added to the same total.
If the first weight is recorded in gross, the future ones should be recorded in the same way. It is the same
for net weight.

3.2.3 Check

Use this application to compare the weight of items to a target weight range. This mode is available for
Weighing, Counting, Percent, and Dynamic.
3.2.3.1 Set Check Limits
i-DT61PW
1.
Press the Target button from Weighing, Counting, Percent or Dynamic mode to set check limits.
2.
The display shows
3.
Press the Yes button to edit the under value.
4.
If there is a stored under value of the last time, the display will show it. For example: 1.0kg.
 Press the Yes button if you want to use this value. Then the display shows
 Press the No button if you do not want to use this value, and skip to step 6.
5.
If there is no stored value, the display shows
6.
To set a new under value, short press the No button several times until the desired number appears. Short
press the Yes button to accept the number and move to the next digit. Repeat the process until all the
digits are correct. Press the Yes button to accept the value. Then the display shows
7.
Repeat step 2 to 6 to set the over value.
8.
If the values you set are invalid, the display will show
9.
If the values you set are valid, the display will go to check weighing screen.
i-DT61XWE
Press the Target button from Weighing, Counting, Percent or Dynamic mode to set check limits.
1.
2.
The display shows
Press the Yes button to edit the under value.
3.
4.
If there is a stored under value of the last time, the display will show it.
 Press the Yes button if you want to use this value.
 Press the No button if you do not want to use this value or do not have a stored value. Input the
needed one with the numeric keypad. Press the Yes button to accept the under value.
5.
The display will show
6.
Repeat step 2 and 3 to set the over value.
7.
If the values you set are invalid, the display will show
8.
If the values you set are valid, the display will go to check weighing screen.
3.2.3.2 Positive Check
Positive check is used to determine when the material added to the scale is within the target range. In this case
the under and over values must be positive values. (The over value must be greater than the under value.)
Add material to the scale platform until the display shows it is within the Accept (green) range.
3.2.3.3 Negative Check
Negative check is used to determine when the material removed from the scale is within the target range. In
this case the under and over values are both negative values. The under value must be greater than the over
value. (For example: the under value is -10; the over value is -15).
Place the item to be weighed on the scale and press the
Remove a portion of the item until it is within the acceptable range.
3.2.3.4 Zero Check
Zero check is used when comparing subsequent samples to an initial reference sample. In this case, the under
value must be a negative value and the over value must be a positive one.
Place the reference item on the scale and press the
Remove material from the scale platform until the display shows it is within the Accept (green) range.
UNDEr
.
UNDEr
.
OuEr
.
000000
.
--NO--
and go back to reset.
--NO--
and go back to reset.
button.
button.
EN-17
OuEr
.
OuEr
.

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis