Herunterladen Inhalt Inhalt Diese Seite drucken

Installation, Connecting-Up - Siemens simovert masterdrives DTI Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

All manuals and user guides at all-guides.com
11.2006
3

Installation, Connecting-up

The board is snapped onto a mounting rail. The components must be
wired-up by others.
♦ The board provides no protection against direct contact. Protection
NOTES
♦ Screened cables must be used to prevent EMC disturbance.
♦ Perfect functioning of the board cannot be guaranteed if the
♦ Power- and control cables must be separately routed.
Terminal
X401:
1)
Siemens AG
6SE7087-6CX84-3DB0
SIMOVERT MASTERDRIVES
against direct contact is ensured by mounting it in an enclosure or in
a cabinet.
Screens must be connected at X80 and X81.
permissible cable lengths are exceeded (refer to figs. 5-1 to 5-4). If
longer cable lengths are required, please contact your tachometer
manufacturer or supplier.
Function, information
TTL tachometer
1
Reference potential (M tachometer)
2
Pulse track A
3
Inverted pulse track A
4
Pulse track B
5
Inverted pulse track B
6
Position track (not evaluated)
7
Inverted position track (not evaluated)
Tachometer monitoring track (not
8
evaluated)
9
Inverted tachometer monitoring track
10
5 V tachometer supply
American Wire Gauge
Digital tacho-Interface
Installation, Connecting-up
Cable cross-section
2
1)
[mm
]
AWG
0,5 to 2,5
20 to 14
0,5 to 2,5
20 to 14
0,5 to 2,5
20 to 14
0,5 to 2,5
20 to 14
0,5 to 2,5
20 to 14
0,5 to 2,5
20 to 14
0,5 to 2,5
20 to 14
0,5 to 2,5
20 to 14
0,5 to 2,5
20 to 14
0,5 to 2,5
20 to 14
3-1

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis