R911410786 | PSI6xCx.726
7.1.8
Stepper state outputs
The stepper state outputs refer to the electrode assigned to the actually selected
program.
7.1.9
Monitoring transformer temperature:
The transformer temperature is exclusively monitored via serial input
"Transformer temperature signal". This input is only scanned during a weld
schedule.
0 = Temperature fault
1 = Temperature OK
7.1.10 Weld timer
The weld timer repeats the weld schedule automatically if QStopp was active, a
conditional tolerance band violation of UIP, PSF or FQF occurred and the function
was activated by the user. The repeated weld schedule runs in KSR mode. The
weld timer stores the number of conditional repetitions in a counter shown in the
UIR process overview.
7.1.11 Gun Force selection
The value on the outputs "Proportional valve programmed value" is an absolute
value corresponds to the value stored in the timer. The range of values is
specified externally.
7.1.12 End Of Component
The input „End Of Component" is used for the Q-Stop functionality. The Input
indicates, that all spots on a Component have been done.
7.1.13 Vehicle ident number
The value which is read from the outputs „Vehicle ident number 1..32" at the end
of a weld schedule is written tot he actual value protocol ( „User parameter 6").
Bosch Rexroth AG
43/49