R911337843 | PSI 6xCx.725.xx
8
Status codes
Tab. 10: Status codes
Code (decimal)
Meaning
00
OK
01
Hardware – refer to BOS_6000
02
No schedule programmed == invalid parameters
03
Start inhibited
04
No current
05
Low current
06
High current
07
Low current - series of welds
08
Current measurement range exceeded
09
Weld time too short
10
Weld time too long
11
Diode current too high
12
Weld fault – refer to BOS_6000
13
Q-Stop component
14
Q-Stop spot in series
15
Q-Stop special spot
16
UIP: Violation of the absolute lower tolerance level
17
PSF: Violation of the absolute lower tolerance level
18
UIP: Violation of the absolute upper tolerance level
19
FQF: Violation of the absolute lower tolerance level
20
FQF: Violation of the absolute upper tolerance level
9
Timer diagrams
There are no general timer diagrams available for this type.
Bosch Rexroth AG
41/45
Status codes