Herunterladen Inhalt Inhalt Diese Seite drucken

Scale Mounting - Sony LASERSCALE BS65-Serie Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5-2. Scale Mounting

1 Check there is no dust, etc. on the mounting surface, and
mount the reference plate parallel to the machine guide,
as shown in the figure.
(Fastening torque : 1.4 N
The reference hole is located on the left, as shown in the
figure. Adjust at the right side while observing the flatness
with the lever type dial gauge.
BS65-160R, 360R, 560R, 760R, 960R
Plain washer
(4)
BS65-260R, 460R, 660R, 860R
Plain washer
(4)
Note
The scale is pressed against the reference plate for
parallelism when mounting. The reference plate is vital to
accurate scale mounting. Be sure to mount it exactly as
described in the specifications.
Basis
22
m)
2-M4 x 8
Datum surface
2-M4 x 8
Datum surface
0.01/0.00039" M
2 Attach the scale clamp loosely by using the mounting
screw, as shown in the figure.
BS65-160R, 360R, 560R, 760R, 960R
Set screw (M4 x 8)
Plain washer (4)
Scale clamp
Spacer
BS65-260R, 460R, 660R, 860R
Set screw (M4 x 8)
Plain washer (4)
Scale clamp
Spacer
3 Check the mounting surface and the abutment surface of
the scale for dust or dirt. Check if the mounting surface and
Datum surface are free from dust or dirt. If not, wipe the
surfaces with gauze moistened with alcohol.
Reference plate
Reference plate
Mounting surface
Datum surface