Function
Output Voltage
RCD Test
Last Error Code
Battery Capacity
Power-Saving Mode
-
Sleep mode
Low Voltage Cut-off
Output Frequency
Explanation
Here the desired alternating
voltage can be set.
Note: Only if the
requirement calls for a
different AC voltage!
Here the function of the
integrated fault current
circuit breaker can be tested.
Display of the last error
codes.
Specifies the battery capacity
in Ah connected to the
inverter. The value in Ah is
used to calculate the input
current and the remaining
runtime. This function is only
possible in conjunction with
a connected measuring shunt
(Current-Sensor).
If the inverter does not
detect a load on the inverter
output for at least 10
minutes, the device enters
Power-Saving Mode.
The LED flashes green.
If the battery voltage drops
to the set value on
the
device, the inverter is
disconnected from the
battery.
Here the desired output
frequency is set on the
device.
Note: Change only if the
application requires a
different output frequency.
VOLTIMA VSI/VST Series
Standard
Setting
Setting
Options
200V/220V
230V
230V/240V
Not
Available
Available
Available
Available
90Ah - 540Ah
90Ah
(at 30Ah intervals)
ON
ON/OFF
9.5V - 11.5V
10.0V
(at 0.5V intervals)
50hz
50Hz/60Hz
83