Note!
Note the starting currents!
When connecting inductive devices (electrical operation e.g. drill, refrigerator, etc.), note that
they often require a 3-10 times higher surge power at short notice to start up than indicated
on the type plate. The maximum short-term power query must not exceed the maximum
power of the inverter.
Note!
Observe acoustic signals!
In the event of an overload, an acoustic signal will sound. If the required power is not reduced
to the maximum continuous power within the specified time, the inverter switches off
automatically.
Note!
Loss of performance due to heat!
At ambient temperatures above 40°C (e.g. due to hot installation locations or direct sunlight)
the predetermined performances and efficiency levels are reduced.
Recommended environmental conditions:
Max. Working temperature
Max. Storage temperature
Max. Relative humidity
Efficiency range*:
System voltage
12V
24V
* Actual efficiencies depend on the type of consumer and utilization. For example, the inverter typically has the
highest efficiencies at a load of approx. 75%.
VOLTIMA VSI/VST Series
-15°C to +50°C
-25°C to +85°C
20% to +80%
VSI/VSTSeries
> 90%
> 90%