Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data; Accuracy; Ambient Conditions 2); Supply Voltage (External) - Balluff BTL7-A510-M Serie Betriebsanleitung

Micropulse wegaufnehmer - bauform stab
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BTL7-A/G510-M _ _ _ _ -H/W(8)-SA378-S32/S115/_ _ _
Micropulse Transducer - Rod Style
10

Technical data

10.1

Accuracy

The specifications are typical values for the BTL7-A/G... at
24 V DC and room temperature, with a nominal length of
500 mm in conjunction with the BTL-P-1013-4R,
BTL-P-1013-4S, BTL-P-1012-4R or BTL-P-1014-2R
magnet.
The BTL is ready immediately, full accuracy after warm-up
phase.
Repeat accuracy
Typical
Sampling rate
Dependent on the nominal length
At nominal length = 500 mm
Non-linearity at
Nominal length ≤ 500 mm
Nominal length > 500 to ≤ 5500 mm
Nominal length > 5500 mm
Temperature coefficient
1)
Max. detectable velocity
10.2
Ambient conditions
Operating temperature
Storage temperature
Relative humidity
Rod pressure rating (when
installed in hydraulic cylinders)
For Ø 8 mm
For Ø 10.2 mm
Shock rating
per EN 60068-2-27
3)
Continuous shock
per EN 60068-2-29
3)
Vibration
per EN 60068-2-6
3)
(note resonant frequency
of the rod)
Degree of protection per
IEC 60529
Connector S32/S115
(when attached)
Cable
20
english
±10 µm
250 µs to 5.5 ms
500 µs
±50 µm
±0.01% FS
±0.02% FS
≤ 30 ppm/K
10 m/s
2)
-40°C to +85°C
-40°C to +100°C
< 90%, non-
condensing
< 250 bar
< 600 bar
150 g/6 ms
150 g/2 ms
20 g, 10 to 2000 Hz
IP 67
IP 68
3)
10.3

Supply voltage (external)

Voltage, stabilized
:
4)
BTL7-_5_ _-...
Ripple
Current draw (at 24 V DC)
Inrush current
Reverse polarity
protection
5)
Overvoltage protection
Dielectric strength
(GND to housing)
10.4

Output

BTL7-A... Output voltage
Load current
BTL7-G... Output voltage
Load current
Short circuit resistance
10.5

Input

Programming inputs La, Lb:
BTL7-_5_ _-...
Overvoltage protection
Nominal length = 500 mm, magnet in the middle of the measuring range
1)
For
: Use in enclosed spaces and up to a height of 2000 m above
2)
sea level.
Individual specifications as per Balluff factory standard
3)
For
: The transducer must be externally connected via a limited-
4)
energy circuit as defined in UL 61010-1, a low-power source as defined
in UL 60950-1, or a class 2 power supply as defined in UL 1310 or
UL 1585.
A prerequisite is that no current can flow between GND and 0 V in the
5)
event of polarity reversal.
10 to 30 V DC
≤ 0.5 V
ss
< 120 mA
≤ 500 mA/10 ms
Up to 36 V
Up to 36 V
500 V AC
0 to 10 V
≤ 5 mA
-10 to 10 V
≤ 5 mA
Signal cable to 36 V
Signal cable to GND
High-active
10 to 30 V DC
up to 36 V

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Btl7-g510-m serie

Inhaltsverzeichnis