Type Code Breakdown - Balluff BTL7-A510-M Serie Betriebsanleitung

Micropulse wegaufnehmer - bauform stab
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BTL7-A/G510-M _ _ _ _ -H/W(8)-SA378-S32/S115/_ _ _
Micropulse Transducer - Rod Style
12

Type code breakdown

Micropulse transducer
Interface:
A = Analog interface, voltage output 0 to 10 V
G = Analog interface, voltage output -10 to 10 V
Supply voltage:
5 = 10 to 30 V DC
Output gradient:
10 = Rising (e.g. A_10 = 0 to 10 V and 0 to 10 V)
Nominal length (4-digit):
M0500 = Metric specification in mm, nominal length 500 mm
(M0025...M7620: H/W)
(M0025...M1016: H8/W8)
Rod version, fastening:
H = Metric mounting thread M18×1.5, O-ring, rod diameter 10.2 mm
W = 3/4"-16UNF thread, O-ring, rod diameter 10.2 mm
H8 = Metric mounting thread M18×1.5, O-ring, rod diameter 8 mm
W8 = 3/4"-16UNF thread, O-ring, rod diameter 8 mm
Special version:
SA378 = Both outputs can be set separately. Both outputs rising.
Electrical connection:
S32 =
8-pin, M16 plug per IEC 130-9, axial
S115 =
8-pin, M12 plug, axial
KA05 =
Cable, 5 m, axial (PUR)
K05 =
Cable, 5 m, radial (PUR)
FA05 =
Cable, 5 m, axial (PTFE)
F05 =
Cable, 5 m, radial (PTFE)
www.balluff.com