Malfunction
Automatic gun does
not shut off material.
Corrosion on air cap
thread, material pas-
sage or nozzle head.
Air escapes from the
end cap inspection
hole (optionally from
material flow control
or regulating cap).
Material leaks from
behind the paint
needle seal through
the gun body inspec-
tion hole.
Automatic gun
SATA ROB Automatic Gun Operating Instructions
Cause
Nozzle set worn.
The sleeve of the
control piston or
paint needle seal
retainer is soiled or
worn.
Control air pressure
is constantly pres-
ent.
Unsuitable cleaning
solution.
Defective seal re-
tainer (air side).
Defective seal or
sleeve.
Defective paint nee-
dle seal.
Paint needle clogged
or damaged.
Contamination be-
tween paint needle
tip and fluid tip.
Damaged nozzle
set.
Corrective action
Replace nozzle set
(see chapter 10.1).
Clean control piston
seat. Replace seal
retainer if necessary
(see chapter 10.4).
Release control air
pressure.
Replace nozzle
head. Heed cleaning
instructions (see
chapter 10.3).
Replace paint nee-
dle seal retainer
(see chapter 10.3).
Replace seal or
sleeve (see chapter
10.4).
Replace paint nee-
dle seal retainer
(see chapter 10.3).
Replace nozzle set
(see chapter 10.1).
Clean fluid tip and
paint needle.
Replace nozzle set
(see chapter 10.1).