Safety instructions

SAFETY INSTRUCTIONS
CAUTION!
Risk of injury!
Use the machine and the extension ca-
ble only in perfect working order. Dama-
ged equipment may not be operated.
Do not disable safety and protective de-
vices!
Children, or people who are not familiar with
the operating instructions, are not allowed to
use the machine.
Never lift, transport or suspend the unit using
the connection cable.
Unilateral modifications or conversions of the
unit are prohibited.
Electrical safety
CAUTION!
Danger from contact with live parts!
Immediately disconnect the plug from
the mains if the extension cable has
been damaged or cut. We recommend
connection via an earth leakage circuit
breaker (ELCB) with a rated leakage cur-
rent < 30 mA.
The pump may not be operated while people
are in the pool or pond.
The mains voltage at your location must com-
ply with the information regarding mains vol-
tage in the Technical Data. Do not use any
other supply voltage.
The appliance must only be operated on
electrical equipment in accordance with DIN/
VDE 0100, parts 737, 738 and 702. For fuse
protection, a circuit breaker of 10 A and an
earth leakage circuit breaker with a rated lea-
kage current of 10/30 mA must be installed.
Only use extension leads approved for out-
door use with a minimum cross-section of
1.5 mm
. Always fully unwind cable drums.
2
Damaged or fragile extension cables may not
be used.
➯ Check the condition of you extension ca-
ble prior for every use.
If the connection cable must be extended,
only a cable type H07RN-F and a moulded
sleeve must be used. This work must only be
carried out by an electrician.
469873_a

INSTALLATION

Mounting the pressure line (03)
The pump has a check valve on the
pump outlet. This prevents the pressure
line being emptied each time the pump
stops.
1. Mount the pressure line (03/1) on the pres-
sure line connection (03/2).
2. Attach the connection cable (03/3) to the pres-
sure line with cable ties (03/4).
3. Prior to immersion of the pump in the well and
shafts, attach the enclosed cable to the cable
lugs (03/5).

STARTUP

Safety
CAUTION!
Exclude, by suitable means, that, in the
event of a fault in the immersion pump,
consequential damage is caused by floo-
ding.
Operate the immersion pump hanging on a
cable.
Operate the appliance only if the immersion
pump is fully immersed.
Always observe sufficient distance to the
base of the shaft (min. 1 m).
Never allow the immersion pump to run
against a closed off pressure line.
When using in shafts, make sure the size is
adequate.
Always cover the shaft with a secure foot-
plate.
Dismantling the pump base (04)
In order to operate the pump in a narrow shaft of
min. 100 mm diameter, the pump base base must
be removed.
1. Unscrew (04/a) both fastening screws (04/1)
of the pump base (04/2).
2. Remove (04/b) pump base (04/2) from the
pump (04/3).

OPERATION

Lowering the pump
When lowering and pulling up the pump in a shaft,
make sure that the mains supply cable is not sub-
ject to tensile stress and that no objects fall into