Maintenance And Care; Storage; Help In Case Of Malfunction - AL-KO TBP 6000/7 Betriebsanleitung

Tiefbrunnenpumpe
Vorschau ausblenden Andere Handbücher für TBP 6000/7:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
en
the shaft. These can jam between the pump hou-
sing and shaft wall so that the pump cannot be
pulled up again.
Switching the pump on
CAUTION!
The immersion pump must not draw in
any solid bodies. Sand and other abra-
sive materials in the conveying medium
will destroy the immersion pump.
1. Fully unwind the mains connection cable.
2. Make sure that the electrical plug connection
is mounted in the area safe from flooding.
3. Insert the mains plug into the plug socket.
Switching the pump off
1. Remove the mains plug from the plug socket.

MAINTENANCE AND CARE

Cleaning the pump
After
conveying
swimming pool water or fluids that leave
a residue, the pump must be flushed out
with clear water.

HELP IN CASE OF MALFUNCTION

CAUTION!
Disconnect the mains plug before any fault rectification work! Faults in the electrical system
must be rectified by a qualified electrician.
The appliance must not be included in the normal household rubbish, but must be properly
disposed of.
Important for Germany: Dispose the appliance at a municipal recycling collection centre.
Malfunction
Motor does not
run.
Pump running, but
does not feed.
12
chlorine-containing
Possible cause
Impeller blocked
Thermal protection switch has swit-
ched off.
No mains power.
Blockage on the suction side.
Pressure line closed off.
Pressure hose kinked.
1. Clean the suction slots on the suction foot if
necessary with clear water.
Checking the cable
1. Pull the pump out of the shaft from time to
time.
2. Check the cable. If the cable is damaged, re-
place it with an original spare part.
3. Check that the cable lugs on the pump are still
durable.
If the cable is damaged, carefully try to pull the
pump out of the shaft via the pressure line. Never
pull on the mains supply cable.

STORAGE

If there is the danger of frost, the sys-
tem must be completely drained and the
pump must be stored in a frost-proof
place.
Solution
Remove dirt from the suction area.
Wait until the thermal protection switch
on the immersion pump switches on
again. Take note of the maximum tem-
perature of the conveying medium.
Have the immersion pump inspected.
Check fuses, have the power supply
checked by a qualified electrician.
Remove dirt from the suction area.
Open the pressure lone.
Extend the pressure hose.
Operation
TBP 6000/7

Werbung

Inhaltsverzeichnis
loading