Herunterladen Inhalt Inhalt Diese Seite drucken

Scope Of Delivery; Safety Instructions - AL-KO HW 4000 FCS Betriebsanleitung

Vorschau ausblenden Andere Handbücher für HW 4000 FCS:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
en
Designated use
The house water system is designed for private
use in the house and garden and is suitable ex-
clusively for the conveying of clear water and rain-
water.
The house water system is suitable for:
Watering the garden and premises
Water supply in the house
Pressure increase in the water supply.
If the pressure of the water supply is in-
ADVICE
creased, the local regulations must be
observed. Your sanitation expert will pro-
vide the necessary information.
Possible misuse
The house water system is not suitable for the
conveying:
Water containing sand, salt water and waste
water with textile and paper content
Aggressive, corrosive, explosive or fuming
chemicals or liquids
Fluids above 35°C.
The house water system must not be
ADVICE
used for conveying water for foodstuffs
or beverages.
The house water system is not suitable
for continuous use.

SCOPE OF DELIVERY

The hot water system is supplied ready for ope-
ration, with key for filter cover, elbow nipple and
operating instructions
Thermal protection
The unit is fitted with a thermal protection switch
which switches the motor off in the event of over-
heating. The pump switches on again automati-
cally after a cooling down period of approx. 15 -
20 minutes.
Dry-run protection
The house water system is provided with a dry
running protection system. The dry running pro-
tection system switches the pump off after approx.
90 seconds if water is not being drawn up or if the
suction line is damaged.
Pressure switch
The house water system is provided with a pres-
sure switch. This pressure switch automatically
14
switches the pump off and on when the set pres-
sure is reached.
Set pressure values: see technical data.
LED monitoring
For monitoring the operational conditions, and for
displaying the fault messages, the house water
system is equipped with LED monitoring.

SAFETY INSTRUCTIONS

CAUTION!
Danger of injury!
Only use the machine and the extension
cable if it is in perfect technical condition!
Damaged units must not be used.
Safety and protective devices must not
be deactivated!
Children, or people who are not familiar with
the operating instructions, are not allowed to
use the machine.
Never lift, transport or suspend the unit using
the connection cable.
Unilateral modifications or conversions of the
unit are prohibited.
Electrical safety
CAUTION!
Danger when touching voltage con-
ducting parts!
Disconnect the plug from the mains if the
extension cable is damaged or severed!
We recommend connecting a RCD (re-
sidual current operated device) having a
nominal residual current of < 30 mA.
The house mains voltage must agree with the
details quoted in the technical data, do not
use any other supply voltage.
The unit must only be operated with an
electrical installation in accordance with DIN/
VDE 0100, Part 737, 738 and 702 (swimming
pools). Protection must be provided by a 10 A
line protection switch and a RCCD (residual
current operated device) having a nominal re-
sidual current of 10/30 mA.
Use only extension cables that are suitable
for use outdoors - minimum cross-section 1.5
mm
. Cable drums should always be unrolled
2
completely.
Product description
HWA 4000 / 4500 FCS

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Hw 4500 fcs

Inhaltsverzeichnis