Herunterladen Inhalt Inhalt Diese Seite drucken

Palazzetti EASY TOUCH Verwendung Und Betrieb Seite 33

Vorschau ausblenden Andere Handbücher für EASY TOUCH:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 35
CODE
ERROR/WARNING
E001
Defective control panel
Error of communication with
E002
the remote control
E004
Communication error
Ignition failure error
E101
Excessively hot supply water
Burn pot emptying system
E104
error
Temperature probe
E105
malfunction
Temperature probe
E106
malfunction
E108
Safety error
Pressure or thermal safety
E109
error
T e m p e r a t u r e
E110
malfunction
E111
Fume probe malfunction
Low pellet level
A001
(flashing icon)
Scheduled maintenance
A002
notification
(flashing icons)
A004
Low spare battery warning
Pressure sensor malfunction
A007
(flashing icon)
----
Stove cleaning
----
Ignition failure error
After checking the message type, it is possible to reset the alarm by pressing the on/off key
for a few seconds.
In case of error "E109 or E108", reactivate the manual reset thermostat on the back of the
stove before resetting the alarm.
At this point it is possible to proceed with a new ignition.
DESCRIPTION
Defectiveness of the control panel
Defectiveness of the control panel
Connection cable between board and control
panel interrupted or disconnected
If it appears during the configuration change,
ignore this error
Insufficient pellets
Pellet quality
Faulty ignition system
Dirty burn pot
Problems on the heating system
Circulator problems
Incorrect burn pot positioning
Defective return water probe
Defective puffer probe
Loading door or hatch open
Dirty fume evacuation system
Worn sealing gaskets
Insufficient combustion air
Problems on the heating system
Circulator problems
Problems of overheating of the pellet tank
Defective supply water probe
p r o b e
Defective air probe
Defective fume temperature probe
(Where present) Low level of pellets
Periodically, the stove requires maintenance
by a specialist technician
The battery is flat and should therefore be
replaced with a new one
Pressure sensor or faults card
Combustion chamber, burn pot or dirty fume
evacuation
Detached or blocked pressure sensing tubes
Blocked combustion air intake
Low level of pellets; ignition resistance faulty;
worn seals; Incorrect burn pot position
004778190 - 15/01/2020 - PN - Italy
POSSIBLE CAUSES
LED
33

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis