3.4 Operation with room thermostat

When the stove is controlled by an external thermostat (or chronothermostat), the installer
must have set the configuration 1.
In this configuration the stove switches off when the external thermostat is satisfied (open
circuit) or modulates its operation (i.e. the stove tries to maintain the desired temperature
while consuming as little as possible) when the set water temperature is reached.
The stove switches back on automatically when the temperature falls below the value set
on the external thermostat (closed circuit).
With the first ignition, or if the switch-off has occurred directly from the stove (key
the stove must be switched on directly from the control panel.
The stove will also switch off in the event that the water temperature continues to rise despite
modulation. In this case the stove will only come back on if the temperature difference between
the set value and the actual value is greater than 20°C.
It is therefore advisable, in this configuration, to set the water temperature to a high value (e.g.
70°C).

3.5 Operation with room probe on the boiler

The stove can be switched on/off manually or in a programmed way.
In this type of configuration, the stove modulates the power according to the ambient
temperature read by the probe on board (i.e. the stove seeks to maintain the desired
temperature while consuming as little as possible).
In the event that the user has enabled the "Eco-mode" function in the submenu [7]
of the Set-up menu , the stove, instead of modulating, switches off when the set
temperature is reached, and switches back on when the room temperature falls below
the delta indicated in submenu [7] of the Set-up menu
IT IS possible to set the desired room temperature in the temperature menu
In the submenu [6] of the Set-up menu
supply water (be advised by your thermo-hydraulic installer of the most suitable temperature
for your heating system).

3.6 Operation in combination with a storage tank

For operation in combination with a storage tank, the installer will have set the operating
configuration 3 or 4 depending on whether it is a storage tank with or without an internal coil.
The boiler is controlled by the temperature read by the probe in the storage.
When the storage temperature set in the temperature menu is reached,
switches off and switches on again if the temperature falls below the delta indicated in
the submenu [8] of the set-up menu.
The antifreeze function can also be set in this configuration.
28
it is possible to set the desired temperature of the
004778190 - 15/01/2020 - PN - Italy
.
.
),
the boiler