Verfügbare Sprachen

4.4.1. OVERLOADS
„ Limit measuring time above 1000 A.
Intensity
Operation
(1) With a frequency F ≤ 1 kHz except C173
C173 with frequency ≤ 500 Hz :
- permanent up to 800 A
- permanent up to 1000 A if temperature ≤ 40 °C
- 15 min. on, followed by 30 min. off for 1000 A < I < 1200 A
4.4.2. FREQUENCY
„ C100 / C102 / C103 / C106 / C107 / C112 / C113 / C116 / C117 / C122 :
- Use : 30 Hz to 5 kHz
- Current limitation beyond 1 kHz as per following formula :
„ C148 :
- Use : 48 Hz to 1 kHz
„ C160 :
- Use : 10 Hz to 100 kHz (-3 dB from 50 kHz to 100 kHz)
- Current limitation beyond 1 kHz as per following formula :
„ C173 :
- Use :
10 Hz to 1 kHz for 1000 A calibre
10 Hz to 3 kHz for other calibres
- Current limitation beyond 500 Hz as per following formula :

4.4.3. ENVIRONMENTAL CONDITIONS

„ Indoor use
„ Altitude :
„ Climatic conditions
„ Avoid splashing with water

4.5. DIMENSIONS AND WEIGHT

„ Overall dimensions
„ Weight
„ Jaw opening
„ Open jaw height
„ Max. clamping capacity
I
≤ 1000 A~
Permanent (1)
: ≤ 2000 m
: -10 to +55 °C and RH < 85%
: 216 x 111 x 45 mm
: approx. 550 g
: 53 mm
: 139 mm
: ∅ 52 mm cable or 1 5x5 mm bar or 4 30x5 mm bars
14
1000 A~ < I
15 minutes on, followed by 30 minutes off
≤ 1200 A~