Function
Configuring the outputs
Outputs are set to PNP, push-pull or NPN by pressing the P or the N key.
The respective circuit diagram is displayed.
Configuring the outputs
Outputs can be set up as normally open or normally closed by pressing the NO
or the NC key. The respective circuit diagram is displayed.
Adjusting ON Delay
On-delay can be set to a value within
a range of 0 to 10,000 ms by pressing
the + or the – key..
Adjusting OFF Delay
Off-delay is adjusted by pressing the
+ or the – key. Off-delay is disabled if
a impulse duration has already been
selected. If this is the case, Impulse!
appears at the control panel.
Adjusting imulse duration
Impulse duration defines how long the
output signal remains in the activated
state. Impulse duration can be set to a
value within a range of 0 to 10,000 ms
by pressing the + or the – key. After
the selected impulse duration has
elapsed, the output signal is returned
to the deactivated state..
www.wenglor.com
46
Object
Output
Object
Impulse
Sensors for your success
Key designation
P
NO
+
Object
Output
+
OFF Delay
+
Impulse duration
On Delay
Impulse duration
Function can be combined with
ON-delay.
www.wenglor.com
N
NC
ON Delay