CD20, CD30
Radio or television interference in the vehicle
Feature
Reception interference
when the compressor
is running
12

Technical data

Connection voltage:
Switch-off voltage:
Switch-on voltage:
Rated current:
Cooling capacity:
Capacity:
Climatic class:
Ambient temperature:
Relative humidity:
Permanent inclination:
Refrigerant quantity:
CO
equivalent:
2
Global warming potential
(GWP):
Dimensions:
Weight:
EN
Possible cause
The electronic connection of
the cooling device is not
directly clamped on to the bat-
tery
CD20
20 l
35 g
0.050 t
16.1 kg
Remedy
Connect the cooling device as
directly as possible to the bat-
tery
12 Vg/24 Vg
10.4 V at 12 Vg
22.8 V at 24 Vg
11.7 V at 12 Vg
24.2 V at 24 Vg
12 Vg: 3 A
24 Vg: 1.5 A
–2 °C bis +12 °C
N
+16 °C to +32 °C
max. 90 %
max. 30°
1430
fig. 1, page 3
Technical data
CD30
30 l
42 g
0.060 t
18 kg