TROUBLESHOOTING

Before calling for service, please review the Troubleshooting list below, since the problem may not be a main unit
malfunction.
SYMPTOM
Odours and smoke are not removed.
The Cleanliness Monitor illuminates blue
even when the air is impure.
The Cleanliness Monitor illuminates or-
ange or red even when the air is clean.
A clicking or ticking sound is heard from
the main unit.
The discharged air has an odour.
The main unit does not operate properly
when cigarette smoke is in the air.
Smell from a new filter.
The Cleanliness Monitor is turned off.
The Cleanliness Monitor lights change
colour frequently.
The SLEEP lamp is flashing.
AUTO RESTART
After a power failure, automatically
resume the operation when the power
recovers.
ON
(default)
(with the main unit OFF)
(simultaneously for
more than 3 sec.)
• Replace the filters if they appear to be heavily soiled. (page 9)
• Check if the plastic bag is removed from the filter. (page 5)
• The air could be impure at the time the main unit was plugged in.
Unplug the main unit, wait one minute, and plug the main unit in again.
• Sensor operation is affected if the dust sensor openings are dirty or
clogged. Gently clean the dust sensor openings. (page 8).
• Clicking or ticking sounds may be audible when the main unit is
generating ions.
• Check to see if the filters are heavily soiled.
• Clean or replace the filters.
• Is the main unit installed in a location that is difficult for the sensor to
detect cigarette smoke?
• Is the dust sensor opening blocked or clogged?
(In this case, clean the opening.) (page 8)
• Immediately after removing the plastic bag, a slight odour may occur.
This odour is not harmful for filter performance or human exposure.
• Check to see if the Lights OFF Mode selected.
Press
for 3 seconds to light On. (page 7)
• Check to see if the SLEEP mode is selected.
The Cleanliness Monitor / Plasmacluster Ion Light are turned off automat-
ically when room is dark after the SLEEP mode is selected.
• The Cleanliness Monitor lights automatically change colours as impurities
are detected by the dust sensor.
• Fan motor error. Turn the power OFF.
Wait one minute, and then turn the power ON.
Even when the plug is unplugged or the breaker is thrown during the
operation, the operation resumes at the previous operation mode and
settings if the power recovers.
If the
,
,
,
lamp Lights up for 8
seconds, the setting is completed.
EN-10
REMEDY (not a malfunction)
OFF
(with the main unit OFF)
(simultaneously for
more than 3 sec.)