40
3.2.1b - MODELS
25GE VAP / 45GE VAP / 46PE VAP / 61GE VAP / 64PE VAP / 101GE VAP / 104PEVAP
START/STOP BUTTON
Pressing START/STOP:
starts the cooking cycle. The internal light comes on, (the cycle
never starts during or at the end of setting without the explicit
START command).
The temperature display changes from showing the set point to
showing the chamber temperature and the corresponding LED
lights up until the set point is reached. It goes off beyond the
set point and comes back on again below the set point.
The timer display changes from showing the set point to showing
a countdown and the corresponding LED flashes, stopping
flashing at the end of the time.
The humidity display remains fixed at the value set and the
corresponding LED lights up when humidification is activated.
The programs display remains set to manual MA or, if a program
is set, it shows the number of the program set and the relative
working phase if set.
Pressing the STOP button again during the cooking cycle:
suspends the cooking cycle.
All the parameters set are maintained.
The cooking time will resume from the suspended time.
Pressing START/STOP again resumes the cooking cycle,
maintaining the parameters set (modified if applicable) at the
time.
At the end of the cooking cycle:
The tune will sound for 10 seconds or until the door is opened
and the oven switches to OFF.
Opening the door while the oven is operating is equivalent to
pressing the stop button, except that, when the door is closed
again, the oven starts again automatically.
pict. 14