Herunterladen Inhalt Inhalt Diese Seite drucken

Wiring - Garbin 25GE VAP Installationsanleitungen

Lektrische umluftöfen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 80
Before starting the oven, remove the protective film from the external walls; remove any
residuals of glue from the surfaces using a suitable solvent.
• The oven can be installed on a fixed counter (with feet) or on a special support stand supplied by the
Manufacturer as an accessory.
• In any case:
a) the oven must be perfectly stable;
b) the oven is not suitable for recess mounting or for installation in sets.
c) During installation on the bench, level the oven using the adjustable feet (see figure 4).

2.2 - Wiring

Connection to the power mains
• Connection to the power mains must be made according to the regulations in force.
• Before connection, ensure that the mains voltage and frequency correspond to the values shown on the
oven rating plate (pict. 1), located at the bottom of the rear panel.
A voltage variation of
• The oven must be connected to the power mains permanently using an H07RN-F-type heavy rubber
cable in neoprene with wires featuring a cross-section suitable for the maximum power demand (see
paragraph 1.4).
• An omnipolar master switch must be placed between each oven and the mains, with at least a 3mm gap
between contacts: capacity must be suitable for the load, and it must feature devices protecting the
supply line.
• Suitable automatic high-sensitivity ground fault interrupters must be installed to assure protection against
direct and indirect contact of live parts and fault currents towards earth according to the regulations in
force. The maximum allowed leakage current is 1 mA/kW.
• This switch must be installed in the permanent electrical system of the facility where the appliance is
installed, and in the immediate vicinity of the actual appliance where it can be reached easily by operators.
• Check data in the specifications table for appropriate sizing of the supply line, master switch and cable.
(see paragraph 1.4).
±
10 % is allowed.
ELECTRIC VENTILATED OVENS
pict. 4
32
GB

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis