Product description,
Air flow
The following describes and illustrates the air flow in a HCH 5 and HCH 8:
No.
5
continued
Outside air (T1)
Outside air which enters the heat exchanger is ready to
be heated by the extract air from the house. ()
Supply air (T2)
The supply air is heated by the means of heat recircula-
tion from the extract air. ()
Extract air (T3)
"Polluted" and warm extract air is used to heat up the
outside air () by the means of heat exchange in the
heat exchanger.
Exhaust air (T4)
The heat of the extract air is use to heat up the cold out-
side air (). The exhaust air is led out of the house.