Seite 1
HCH 5 og HCH 8 Brugervejledning No. 060798 • rev. 1.2 • 26.04.2011 Brugervejledning til HCH 5 og HCH 8 Side User’s guide for HCH 5 and HCH 8 Page Bedienungsanleitung für HCH 5 und HCH 8 Seite...
Seite 2
Der tages forbehold for trykfejl og ændringer Dantherm can accept no responsibility for possible errors and changes Irrtümer und Änderungen vorbehalten Dantherm n’assume aucune responsabilité pour erreurs et modifications éventuelles...
Introduktion Overblik Introduktion Dette er brugervejledningen for boligventilationsaggregaterne HCH 5 og HCH 8 fra Dantherm Air Handling. Indholdsfortegnelsen nedenfor giver et overblik over vejledningens afsnit. Serienummer For fremtidige henvendelser om fx reservedele beder vi dig notere det nøjagtige serie- nummer på aggregatet her: ______________________ Denne vejledning dækker aggregater med serienumre lig med eller højere end:...
Kopiering af servicemanualen eller dele af den er ikke tilladt uden en skriftlig tilladelse fra Dantherm Air Handling A/S. Forbehold Dantherm Air Handling A/S forbeholder sig retten til til hver en tid at foretage ændringer og forbedringer på produktet og i brugervejledningen uden forudgående meddelelse el- ler forpligtelser.
Introduktion Dette afsnit giver en beskrivelse af aggregatet. Brugen af HCH 5 HCH 5 og HCH 8 bruges til ventilation af private boliger. og HCH 8 Aggregatet leverer frisk opvarmet udeluft gennem aggregatet til boligen. Forurenet og varm udsugningsluft udnyttes til at varme udeluften op med ved hjælp af varmegenvinding.
Seite 6
Produktbeskrivelse, fortsat Luftflow Det følgende beskriver og illustrerer luftflowet i HCH 5 og HCH 8: Beskrivelse Udeluft der kommer ind i varmeveksleren klar til at bli- Udeluft (T1) ve opvarmet af udsugningsluften fra huset ( ) Indblæsningsluften er varmet op ved hjælp af varme- Indblæsningsluft (T2)
Funktionsbeskrivelse Vigtigt Ventilationssystemet skal altid være i drift! Ud over de 4 timer som aggregatet kan stoppes fra kontrolpanelet er det ikke tilrådeligt at stoppe aggregatet. Risikoen ved at stoppe aggregatet i en længere periode er, at fugtig luft kan kondensere i rørinstallationerne og i ventilationsaggregatet med fare for vandskader i bygningskonstruktionen, skader på...
Seite 8
Funktionsbeskrivelse, fortsat Manuel drift Hvis man ønsker en anden luftmængde end den aggregatet giver i automatisk behovs- styring, kan man manuelt vælge mellem Ventilatortrin 0-4. Se følgende eksempler: Trin Funktion På kontrolpanelet kan aggregatet indstilles til fire forskellige ha- stigheder, Ventilatortrin 1-4. Aggregatet er slukket.
Beskrivelse af kontrolpanelet Introduktion Dette afsnit giver en detaljeret beskrivelse af HCP4 kontrolpanelet. Yderligere funktionsbeskrivelse findes side 7. Illustration Denne illustration viser kontrolpanelet, som via forskellige indikatorer giver information om driften. Kontrolpanelet har tre trykknapper, som let aktiveres: Del/funktion Denne tabel giver en beskrivelse af de forskellige dele på kontrolpanelet: Funktion Driftsindikatoren kan vise tre forskellige tilstande: Driftsindikator...
Seite 10
Beskrivelse af kontrolpanelet, fortsat Del/funktion, fortsat Funktion Ved aktivering af automatisk behovsstyring styrer aggregatet efter luftfugtighed i boligens udsug- ningsluft. Automatisk behovsstyring kører altid på Ventilatortrin 1, 2 eller 3 Automatisk behovs- styring Ved fejl på aggregatet bipper kontrolpanelet én Akustisk filteralarm gang i timen (gælder også...
Betjening Introduktion Dette afsnit beskriver kun, hvordan de forskellige funktioner aktiveres og betjenes. Yderligere information omkring hver enkelt funktion kan ses i afsnittet “Funktionsbeskrivelse”, side 7 eller i afsnittet ”Setpunkter” i installationsvejledningen. Strømbesparelse For at spare på strømmen slukker alt lys – med undtagelse af den grønne lysdiode - i kontrolpanelet efter 2 minutter uden betjening.
Seite 12
Betjening, fortsat Installatørdrift Tryk på Manuel + Auto i 6 sekunder indtil Ventilatortrin 3 lyser. Aggregatet kører i Ventilatortrin 3 i én time. I denne periode overstyres alle andre funktioner. Filterskift/- Filterskift og nulstilling af filteralarm er beskrevet i detaljer i afsnittet ”Forebyggende nulstilling vedligeholdelse”, side 13.
Forebyggende vedligeholdelse Introduktion For at boligventilation kan køre driftsikkert, er det nødvendigt at udføre forebyggende vedligeholdelse i form af udskiftning af filtre og rengøring af aggregatet. Filterskift Udskift filtrene når filteralarmen vises på kontrolpanelet (dioden blinker gult) og den akustiske alarm bipper (én gang i timen). Blinker Trin Handling...
Seite 14
Forebyggende vedligeholdelse, fortsat Rengøring Hold aggregatet rent for at sikre fejlfri drift og god hygiejne. Hvis aggregatet er beskidt, fx omkring filteråbningerne, skal det rengøres med en hårdt opvredet klud med lunken vand, evt. med opvaskemiddel. Vigtigt: Kemiske opløsningsmidler må ikke bruges! Betingelser for Fabriksgarantien er kun gyldig med dokumenteret forebyggende vedligeholdelse.
Tilbehør Introduktion Dette afsnit giver et overblik over tilgængeligt tilbehør til HCH 5 og HCH 8. Der er en li- ste over tilbehøret samt en kort beskrivelse inklusiv et varenummer til ordreafgivelse. Yderligere information kan fås om alle tilbehørsdele hos Dantherm Air Handling A/S, se også...
Seite 16
Måling af CO 063874 Kobles til HAC 1. Varmeflader Komplet liste med illustration, beskrivelse og varenummer for tilgængelige varmeflader til HCH 5 og HCH 8: Tilbehør Illustration Beskrivelse Varenr. Eftervarmeflade Eftervarmefladesæt, Ø 125, komplet.
Seite 17
Komplet liste med illustration, beskrivelse og varenummer for tilgængelige filtre til HCH 5 og HCH 8: Tilbehør Illustration Beskrivelse Varenr. G4 filtersæt Standardfilter, leveres i HCH 5 063470 sæt a to stk. HCH 8 063471 F7 pollenfilter- Ekstra fint filter, som fil- HCH 5 063448 sæt...
Fejlfindingsvejledning Alarmer Lokaliser problemet i venstre kolonne og følg instruktioner mod højre: Alarm Årsag Handling Gul lysdiode (30/min) og Filtrene trænger til efter- Skift filtre og nulstil filterti- biplyd syn/udskiftning meren på aggregatet. Se ”Forebyggende vedlige- holdelse”, side 13 Rød, permanent lysdiode Aggregatet har en elektrisk Kontakt din installatør og biplyd...
Seite 19
Fejlfindingsvejledning, fortsat Gener, fortsat Gene Årsag Handling Aggregatet køler Udeluften bliver muligvis var- Kontakt din installatør ikke nok met op, før den kommer ind i huset. Temperaturne ligger udenfor Tryk på manuel bypass og op- de fastlagte grænser, som nå køling de næste 6 timer skal være opfyldt for at opnå...
Seite 20
Fejlfindingsvejledning, fortsat Gener, fortsat, Lokaliser problemet i venstre kolonne og følg instruktioner mod højre: fort- Problem Årsag Aggregatet kører altid Aggregatet er indstillet til Indstil aggregatet til auto- samme hastighed manuel drift på én bestemt matisk behovsstyring, hastighed hvorefter aggregatet vil til- passe luftmængden i hen- hold til behovet Displayet går ud efter kort...
Seite 23
Introduction Overview Introduction This is the user’s guide for the home ventilation unit HCH 5 and HCH 8 from Dantherm Air Handling. The table of contents below lists the sections in this guide. Serial number For any future inquiries regarding e.g. spare parts we kindly ask you to make a note of...
Copying of this guide, or part of it, is forbidden without prior written permission from Dantherm Air Handling. Reservations Dantherm Air Handling reserves the right change and improve the product(s) and documentation at any time without prior notice or obligation. EC-Declaration of...
This section gives a description of the unit. The use of HCH 5 HCH 5 and HCH 8 are used for ventilation of private houses. and HCH 8 The units provide fresh heated outside air through the unit into the house.
Seite 26
Product description, continued Air flow The following describes and illustrates the air flow in a HCH 5 and HCH 8: Description Outside air which enters the heat exchanger ready for Outside air (T1) heating by the extract air from the house ( ).
Functional description Important The ventilation system must always be operating! Besides the four hours where the unit can be stopped by the control panel, it is not ad- visable to stop the unit. The risk by stopping the unit for a considerable period is that moist air can condense in the ducting system and in the ventilation unit with the risk of water damage in the building construction, damages on the unit and sanitary problems.
Seite 28
Functional description, continued Manual operation In order to change the air flow rate, defined by Automatic Demand Mode, it is possible to select between Fan Step 0 – 4 manually. See the following examples: Fan step Function Fan Step 0 - 4 on the unit is adjustable on the control panel. The unit is turned off.
Seite 29
Functional description, continued Filters The purpose with the filters is to remove dust and other impurities from the outside air before it is supplied into the house, and to protect both the heat exchanger and the fans from any dirt and impurities coming from the house. As a standard the unit is delivered with G4 filters on both the supply air and the extract air sides.
Description of the control panel Introduction This section gives a detailed description of the HCP4 control panel. See also the sec- tion “Functional description” on page 27. Illustration This illustration shows the control panel which informs about the operation of the unit by different kinds of indicators.
Seite 31
Description of the control panel, continued Part/function, con- Part Function tinued Shows the current fan step the unit is operating at. Fan steps By activating Automatic Demand Mode the unit is controlled according to the humidity level of the ex- tract air from the house.
User’s guide Introduction This section only describes how the different functions are activated and operated. For further information regarding each individual function please see the section “Functional description”, on page 27 or the section ”Set points and control strategies” in the installation guide.
Seite 33
Maximum Speed Fan Step 4 operates for four hours. It is especially useful at high room temperatures, e.g. with many people present in the house .The fan speed automatically resets to the last selected fan step. Continued overleaf...
Seite 34
User’s guide, continued Installation Mode Press Manual + Auto for 6 seconds until Fan Step 3 alights. The unit will operate on Fan Step 3 for one hour. Installation Mode overrides all other modes during that period. Change of filters Change of filters and resetting the filter alarm is described in details in the section ”Preventive maintenance”, on page 35 /resetting...
Preventive maintenance Introduction In order for home ventilation to operate safely it is necessary carry out preventive main- tenance, e.g. replacing filters and cleaning the unit. Changing of Change the filters when the filter alarm is visible on the control panel (the diode flashes filters yellow on and off) and the acoustic alarm bleeps (once every hour).
Seite 36
Preventive maintenance, continued Cleaning Keep the unit clean to ensure perfect operation and good hygiene. If the unit is filthy, e.g. around filter openings, clean with a firmly wrung dishcloth with tepid water and detergent. Important: Chemical solvents are not allowed! Terms for war- The factory warranty is only valid when preventive maintenance can be proven.
Accessories Introduction This section lists available accessories for HCH 5 and HCH 8. There is also a brief de- scription including an item number for placing orders. Further information regarding all accessories can be obtained from Dantherm Air Handling A/S. See also www.dantherm-air-handling.com.
Seite 38
Measuring of CO 063874 Connect to HAC 1. Heating coils Complete list with illustrations, descriptions and item numbers for available heating coils for HCH 5 and HCH 8: Accessory Illustration Description Item no. Reheating coil Reheating coil, complete set,...
Seite 39
Ø 160 mm, stand alone Pre/re heating kit, 1800 W, 063855 Ø 250 mm, stand alone Filters Complete list with illustrations, descriptions and item numbers for available filters for HCH 5 and HCH 8: Accessory Illustration Description Item no. G4 filter set...
Fault finding guide Alarms Localise the problem in the left column and follow the instructions in the right column Alarm Cause Action Yellow light-emitting diode The filters need to be Change the filters and re- (30/min) and a beep- checked/changed. set the filter timer on the sound.
Seite 41
Fault finding guide, continued Inconvenience Localise the problem in the left column and follow the instructions in the right column Inconvenience Cause Action Abnormal noise from the Fan Step 4 is activated Turn the unit back to Fan Step unit (only suited for shorter 1, 2, 3 or activate Automatic duration of use).
Seite 42
Fault finding guide, continued Inconvenience, con- Inconvenience Cause Action tinued The house is being The unit might be operating Switch to Automatic Demand unnecessarily dried with too much air change Mode or set the air flow rate at out. compared to the size and use Fan Step 2 or 1 in Manual Op- of the house.
Einführung Überblick Einführung Dies ist die Bedienungsanleitung für die Wohnungslüftungsgeräte HCH 5 und HCH 8 von Dantherm Air Handling. Das unten stehende Inhaltsverzeichnis gibt einen Überblick über die Abschnitte der An- leitung. Seriennummer Für zukünftige Anfragen, z. B. zu Ersatzteilen, bitten wir Sie, hier die genaue Serien- nummer des Geräts einzutragen: ______________________...
Das Kopieren des Bedienungsanleitung oder Teilen daraus ist nur mit schriftlicher Er- laubnis der Dantherm Air Handling A/S gestattet. Vorbehalt Dantherm Air Handling A/S behält sich das Recht zu Änderungen und Verbesserungen am Produkt/an den Produkten und an der Dokumentation jederzeit ohne vorherige An- kündigung oder weitergehende Verpflichtung vor.
Einführung Dieser Abschnitt enthält eine Beschreibung des Geräts. Verwendung des HCH 5 und HCH 8 wird zur Lüftung privater Wohnungen verwendet. HCH 5 und HCH 8 Das Gerät liefert frische, erwärmte Außenluft durch das Gerät in die Wohnung. Verschmutzte und warme Abluft wird verwendet, um die Außenluft mittels Wärmerück- gewinnung zu erwärmen.
Seite 48
Produktbeschreibung, fortgesetzt Luftstrom Nachfolgend wird der Luftstrom in einem HCH 5 und HCH 8 beschrieben und darge- stellt: Beschreibung Außenluft, die in den Wärmetauscher kommt, um Außenluft (T1) durch die Abluft aus dem Haus erwärmt zu werden ( ). Die Einblasluft wurde mittels Wärmerückgewinnung Einblasluft (T2) aus der Abluft ( ) erwärmt.
Funktionsbeschreibung Wichtig Das Lüftungssystem muss immer in Betrieb sein! Abgesehen von den 4 Stunden, die das Gerät vom Bedienpult aus abgeschaltet wer- den kann, ist es nicht ratsam das Gerät abzuschalten. Die Gefahr beim Abschalten des Geräts über einen längeren Zeitraum besteht darin, dass feuchte Luft in den Rohrlei- tungen und im Lüftungsgerät kondensieren kann, was zu Wasserschäden in der Ge- bäudekonstruktion, Schäden am Gerät und Problemen mit der Hygieneführen kann.
Seite 50
Funktionsbeschreibung, fortgesetzt Manueller Betrieb Wenn man eine andere Luftmenge haben möchte als das Gerät in Automatikbedarfs- modus liefert, kann man zwischen den Stufen 0 und 4 wählen. Siehe folgende Beispie- Stufe Funktion Ventilatorstufe 0-4 des Geräts können auf dem Bedienpaneel eingestellt werden.
Seite 51
Funktionsbeschreibung, fortgesetzt Filter Das Ziel der Filter ist das Entfernen von Staub und anderem Schmutz aus der Außen- luft, ehe diese in das Haus geblasen wird, und der Schutz des Wärmetauschers und der Ventilatoren vor dem Ablagern von Schmutz und Dreck, der aus der Wohnung stammt.
Beschreibung des Bedienpults Einführung Dieser Abschnitt enthält eine detaillierte Beschreibung des Bedienpaneels HCP4. Siehe ebenfalls Abschnitt „Funktionsbeschreibung“ auf Seite 49. Abbildung Diese Abbildung zeigt das Bedienpult, das über verschiedene Indikatoren Informatio- nen über den Betrieb zur Verfügung stellt. Das Bedienpult hat drei Drucktaster, die leicht aktiviert werden: Teil/Funktion Diese Tabelle bietet eine Beschreibung der verschiedenen Elemente des Bedienpults: Teil...
Seite 53
Beschreibung des Bedienpults, fortgesetzt Teil/Funktion, fort- Teil Funktion gesetzt Im manuellen Betrieb können Sie das Gerät ausschalten oder in Ventilatorstufe 1 bis 4 laufen lassen. Manueller Betrieb Eine detaillierte Nutzungsbeschreibung der vier Ventilatorstufen finden Sie in Abschnitt „Funktionsbeschreibung“ auf Seite 49 Zeigt die aktive Ventilatorstufe des Geräts.
Bedienung Einführung In diesem Abschnitt wird nur beschrieben, wie die verschiedenen Funktionen akti- viert/bedient werden. Weitere Informationen zur jeweiligen Funktion finden Sie im Abschnitt “Funktionsbeschreibung”, Seite 49 oder im Abschnitt ”Einstellpunkte” in der Installati- onsanleitung. Strom sparen Mit der Energiespareinstellung werden nach zwei Minuten ohne Geräteaktivierung sämtliche Leuchtanzeigen auf dem Bedienpaneel (mit Ausnahme der grünen LE) ab- geschaltet.
Seite 55
Bedienung, fortgesetzt Kaminbetrieb Sechs Sekunden lang drücken, bis auf dem Bedienpaneel Ventilatorstufe 3 aufleuchtet. Das Gerät stoppt die Luftabsaugung und liefert in Ventilatorstufe 3 für weitere 15 Minu- ten Zuluft. Maximum Drehzahl Ventilatorstufe 4 ist vier Stunden lang aktiv. Diese Stufe empfiehlt sich bei hohen Rau- mtemperaturen, wenn sich z.
Vorbeugende Wartung Einführung Damit die Wohnungslüftungsgerät betriebssicher laufen kann, ist die Durchführung ei- ner vorbeugenden Wartung in Form des Austauschens der Filter und der Reinigung des Geräts erforderlich. Filterwechsel Die Filter austauschen, wenn der Filteralarm am Bedienpult erscheint (die Diode blinkt gelb) und der akustische Alarm piepst (ein Mal pro Stunde).
Seite 57
Vorbeugende Wartung, fortgesetzt Reinigung Halten Sie das Gerät sauber, damit ein fehlerfreier Betrieb und eine gute Hygiene ge- währleistet sind. Wenn das Gerät beispielsweise im Bereich der Filteröffnungen verschmutzt ist, mit ei- nem gut ausgewrungenen Spültuch mit lauwarmem Wasser und Reinigungsmittel reini- gen.
Zubehör Einführung In diesem Abschnitt werden die für das HCH 5 und HCH 8 verfügbaren Zubehörteile aufgeführt. Zu den einzelnen Teilen ist jeweils eine Kurzbeschreibung sowie die Arti- kelnummer für Bestellungen angegeben. Weitere Informationen zu sämtlichen Zubehörteilen erhalten Sie von Dantherm Air Handling A/S.
Seite 59
Feuchtigkeit steuern. Sensor Zur Messung von CO 063874 Steuerung über HAC 1. Wärmeflächen Komplette Liste mit Abbildung, Beschreibung und Artikelnummer für verfügbare Wär- meflächen zum HCH 5 und HCH 8: Zubehör Abbildung Beschreibung Artikel-Nr. Nachwärmeflä- Nachwärmeflächesatz, Ø 125, 063843 che (Wasser) komplet.
Seite 60
1200 W, Ø 160 mm, stand alone Vor-/Nachwärmeflächesatz, 063855 1800 W, Ø 250 mm, stand alone Filter Komplette Liste mit Abbildung, Beschreibung und Artikelnummer für verfügbares Filter zum HCH 5 und HCH 8: Zubehör Abbildung Beschreibung Artikel-Nr. G4 Filtersatz Standardfilter, wird in...
Anleitung zur Fehlersuche Alarme Problem in der linken Spalte lokalisieren und den Anweisungen nach rechts folgen: Alarm Ursache Handlung Gelbe Leuchtdiode Die Filter müssen gewar- Filter austauschen und (30/min) und Piepton. tet/ausgetauscht werden. den Filtertimer am Gerät zurücksetzen. Siehe ”Vorbeugende Wartung”, Seite 56.
Seite 62
Anleitung zur Fehlersuche, fortgesetzt Beeinträchtigun- Beeinträchtigung Ursache Handlung gen, fortgesetzt Das Gerät kühlt Die Außenluft kann vor dem Wenden Sie sich an Ihren In- nicht ausreichend. Eintritt in das Haus erwärmt stallateur. werden. Die Temperaturen liegen au- Auf manuellen Bypass drü- ßerhalb der festgelegten cken und in den nächsten 6 Grenzen, die eingehalten wer-...
Seite 63
Anleitung zur Fehlersuche, fortgesetzt Beeinträchtigungen, Beeinträchtigung Ursache Handlung fortgesetzt Auf der Innenseite Der Luftaustausch ist zu ge- Das Gerät auf automatische von Fensterschei- ring, oder aber die Verteilung Bedarfssteuerung stellen, ben und anderen ist so unglücklich, dass die kri- damit es die Feuchtigkeit au- tomatisch auf einem geeigne- kalten Flächen tritt tischen Räume zu wenig Luft...