1. Too much distance hood-hob.
2. Too much draught because of open
doors and/or windows.
1. Screws are not firmly tightened.
2. The mounting bracket / mounting
plate is not fixed firmly.
If the appliance has a malfunction not noted on the schedule or if you have
checked all items on the schedule but the problem still exists, please contact the
shop you purchased the appliance at.
I
F THE HOOD DOES NOT WORK PROPERLY AND
INCREASED OPERATING NOISE
➢ Incorrect dimension of the air duct.
➢ Obstruction in the air duct.
➢ The diameter of the air duct from hood to wall-box inclusive should be 120 mm;
otherwise the capacity of the motor may be decreased.
➢ If you have installed a fly screen on the wall-box, the air vent may be obstructed.
Check by removing the fly screen.
➢ If the cover panel of the wall box is equipped with firm and slanted slats, the air
vent may be obstructed. Check by removing the cover panel.
➢ Install a cover panel with moveable slats, which do not obstruct the air vent.
➢ Check condition and cleanliness of the filters.
➢ Check if the air which is extracted by the hood is replaced to avoid negative
pressure.
➢ When you run your appliance in recirculating mode, check if the carbon filter has
been replaced on time (min. every 3-6 months).
I
NSUFFICIENT EXTRACTING CAPACITY
A
PPLIANCE IS UNSTABLE
~
1. Lower position of hood.
2. Close the doors/windows.
.
1. Tighten the screws.
2. Fix
the
mounting
mounting plate properly.
/
OR YOU CAN HEAR
,