Parameters table
01*
Adjustment of temperature difference before restart
02
Reserved - Do not adjust
Reserved - Do not adjust
03
04
Adjusting the cooling temperature
05
Adjusting the heating temperature
06
Reserved - Do not adjust
07
Reserved - Do not adjust
08
Reserved - Do not adjust
09
Setting the compensation coefficient of the temperature water inlet
10
Reserved - Do not adjust
11
Auto-activation time before de-icing commences
12
De-icing activation temperature
13
Maximum de-icing duration
14
De-icing deactivation temperature
Reserved - Do not adjust
15
16
Reserved - Do not adjust
17
Expansive valve action period
18
Reserved - Do not adjust
19
Reserved - Do not adjust
20
Reserved - Do not adjust
21
The mini opening for the electrical expansive valve
22
Reserved - Do not adjust
23
Reserved - Do not adjust
24
Reserved - Do not adjust
25
Reserved - Do not adjust
Reserved - Do not adjust
26
27
Reserved - Do not adjust
28**
Filtration pump servo-control mode
29
Max waterf outlet temp set in heating mode
*
Parameter 01 allows you to change the lost degree interval from the requested temperature so that the heat pump starts again.
Example : If the value of parameter 01 is 3°C, after reaching the required temperature (eg 27°C), the heat pump will restart when the pool tempe-
rature drops to 24°C (27 - 3).
* *
Parameter 28: Control mode of the circulation pump
When you switch on your heat pump, the circulation pump starts and then 1 minute later, the heat pump compressor is activated. When
the heat pump stops running, its compressor and fan shut off, and after 30 seconds, the circulation pump stops. During a defrost cycle, the
circulation pump will continue to operate regardless of the mode chosen.
Mode 1 : By selecting this mode, the heat pump will automatically put the circulating pump into continuous operation. Once the circulating pump is
operating, the heat pump will start up 1 minute later. Next, when the required temperature is reached, the heat pump will stop working but will not
stop the circulating pump, so as to ensure a constant circulation of water in your heat pump.
Mode 0 : This mode has been designed to maintain filtration in your pool without using the timetable programmer. When the required
temperature is reached, the heat pump will go on standby, then 30 seconds later the circulating pump will shut down. The circulating pump
will then be reactivated in special mode: 2 minutes operation, 15 minutes shut down, thus maintaining regular filtering of your pool. With a
temperature sensor in the heat exchanger compartment, this mode allows your heat pump to update your pool's actual temperature every 15
minutes. We therefore recommend this mode. It is only when the pool temperature goes down by 3°C in relation to the required temperature
that the filtration pump and the heat pump resume their normal operating mode. (This mode is recommended for a direct connection allowing
a delayed start of the circulation pump and the heat pump without going through the timer the circulation pump).
4. Use
Description
28
Adjustment range
Factory setting
1~18°C
1°C
8~28°C
27°C
15~40°C
27°C
-5~15°C
0°C
20~90 min
45 min
-15~1°C
-3°C
5~20 min
8 min
1~40°C
20°C
20~90s
30s
50~150
80
0 ~ 1
1
25~40°C
40
Remarks
Adjustable
Reserved
Reserved
Adjustable
Adjustable
Reserved
Reserved
Reserved
Adjustable
Reserved
Adjustable
Adjustable
Adjustable
Adjustable
Reserved
Reserved
Adjustable
Reserved
Reserved
Reserved
Adjustable
Reserved
Reserved
Reserved
Reserved
Reserved
Reserved
Adjustable