INSTALLATION
GB 24
• 2 phases with 1 zero connection (2L 1N, 400 V ~ / 50 Hz):
▷ The voltage between the phase and the zero is 230 V ~.
Between the lives there is a voltage of 400 V. If there is not
a voltage of 400 V between the lives, two wires have been
taken from the same live in the meter cupboard and the
hob must be connected with two neutral wires, as indicated
above under 2 lives with 2 neutrals. Install a connecting bridge
between the connection points 4-5. Your groups must be fused
with at least 16 A (2x). The core diameter of the connecting
cable must be at least 2.5 mm
• Single phase connection (1L 1N, 230 V ~ / 50 Hz):
▷ The voltage between the phase and the zero is 230 V ~. Install
connecting bridges between connection points 1-2 and 4-5.
Your group must be protected by a fuse of at least 32 A. The
core diameter of the connecting should be at least 6 mm
2
.
2
.