Charging and discharging cycles of NiMH/NiCd batteries 'NiMH CYCLE' and 'NiCd
CYCLE'
To test batteries, form new batteries or refresh older batteries, you can automatically perform
up to 5 charging/discharging cycles in automatic succession. The two possible combinations
are 'Charge/Discharge' ('CHG>DCHG') and 'Discharge/Charge' ('DCHG>CHG'). This mode
uses the charging/discharging current that you configured in the charging ('CHARGE') and
discharging ('DISCHARGE') programmes. The cycle count determines how often the set
sequence of charge/discharge or discharge/charge operations is performed.
Select the desired battery programme for the battery type
(NiMH/NiCd) – 'NiMH CYCLE' or 'NiCd CYCLE'.
You can set the sequence (Charge>Discharge or
Discharge>Charge) on the left and the number of cycles
-
+
-
+
on the right. You can set from 1 to 5 cycles.
Stop
Enter
>3 s
Press the STATUS + (4) and (21) and STATUS - (5) and
(18) buttons to change the process sequence, the number
of cycles or the charging/discharging current setting.
After setting the number of cycles, press and hold the
ENTER
start cycle operation.
Battery
Charging/
Charged/
type
discharging
discharged
The display shows the following data during the charging
current
capacity
or discharging cycle: The battery type is shown at the top
left of the display (NiMH, NiCd). The charging/discharging
Time
Battery
current is shown in the centre and the current battery
passed
voltage
voltage is shown at the top right.
The selected cycle is shown at the bottom left of the
display ('C>D' = charge/discharge, 'D>C' = discharge/
charge). The elapsed charge/discharge time is shown
in the centre of the bottom row next to the charged/
discharged capacity (in mAh).
Press the STOP
cyclical operation.
A beep is sounded when the cycle is complete.
Programme memory, saving battery data 'BATT MEMORY'
The charger has a data memory. The charger has 10 memories in which you can save battery
data/settings. These can be retrieved again later if necessary, so that the settings do not have
to be implemented again every time.
Select the memory setting. To do this, press the STATUS
+ buttons (4) and (21) and STATUS - buttons (5) and (18)
in the main menu to select the 'BATT MEMORY' function.
The memory number flashes on the display.
Use the STATUS + or STATUS - buttons to select one of
Enter
>3 s
the 10 memories.
data, the display shows the battery type and number of
cells as well the charging and discharging current. If the
memory slot is empty, 'ENTER SET' is displayed.
Confirm the memory number selection with the
ENTER
type) is displayed.
Press the STATUS + and STATUS - button to select the
desired setting function (e.g. battery type/number of cells,
charging current, discharging current, cell voltage (TVC),
shut-off temperature, etc.). In the setting example, the
setting is for a LiPo battery (2S/7.4 V). A description of
the other displayed setting functions can be found below.
according to the selected battery type.
If a setting needs to be modified, briefly press the
ENTER button. The value to be set flashes.
Modify the flashing value with the STATUS + and
STATUS - buttons. For quick adjustment, press and hold
the corresponding button for longer.
Complete and confirm the setting by briefly pressing the
ENTER
another setting value, repeat the steps above.
Proceed in the same way to set the other variables in the
settings sequence.
Set the voltage and number of cells (1S - 6S).
Set the charging current in a range of 0.1 to 10.0 A.
Set the discharging current in a range of 0.1 to 5.0 A.
Set the discharging voltage. Setting is possible in a range
of 3.0 - 3.3 V/cell.
button (3) and (20) for more than 3 seconds to
button (6) and (19) to stop the current
If the memory slot already contains battery
button (3) and (20). The first setting (battery
Different setting options are available
button. The set value stops flashing. To select
Set the charging voltage. Setting is possible in a range
of 4.18 - 4.30 V.
Set the shut-off temperature. Setting is possible in a
range of 20°C to 80°C.
Press the ENTER
charging profile data to the memory using the current
memory number. The characteristic values of the profile
are displayed on the LC display (7) and (8).
To discard previous settings and cancel setting mode,
press the ENTER
again.
Repeat this procedure for the other memory spaces.
settings will be lost. The display then shows the indicator
with flashing memory number again.
Enter
>3 s
Next flash
data from the memory' for how to load saved charging/
discharging data for a battery.
The following provides details of the setting parameters and functions:
Different setting functions are available according to the set battery type (LiPo, Li-
ion, LiFe, NiMH, NiCd, Pb). For example, the setting function for the charging end
voltage per cell is only available for lithium batteries.
Select the battery type first, and then the other data, to ensure that the charger
displays the correct setting functions..
You must stop the charging programme to be able to modify settings. You cannot
change the charging current setting during the charging process.
Battery type
Select the battery type (LiPo, Li-ion, LiFe, NiMH, NiCd or Pb).
As stated above, the battery type must be selected first to ensure that the charger
displays the correct setting functions.
Battery voltage
This setting allows you to set the battery voltage for the selected battery type.
It is not possible to set just any voltage; the increment size depends on the rated
voltage of an individual cell of the respective battery type. For example, if the rated voltage of
a cell in a LiPo battery is 3.7 V, the voltage can only be adjusted in increments of 3.7 V (3.7 V,
7.4 V, 11.1 V etc.).
Charging current
Here, set the desired charging current. This must be selected according to the battery used.
A charging current of 0.1 - 10.0 A can be set.
The actual charging current available during the charging process depends on the
battery type and the number of cells. The maximum charging power available per
channel is 100 W.
Discharging current
Here, set the desired discharging current. This must be selected according to the battery used.
A discharging current current of 0.1 - 5.0 A can be set.
The actual discharging current flowing during the discharging process depends on
the battery type and the number of cells. The maximum discharging power per output is 10 W.
Discharging voltage per cell
Here, you can set the voltage per cell at which the discharging process is ended (typically 3 V).
Warning!
Never set the voltage too low. In the case of lithium batteries, this can lead to deep
discharge and permanent damage to the battery. Follow the battery manufacturer's
instructions.
Charging end voltage per cell (TVC)
Here, you can set the voltage per cell at which the charging process for lithium batteries is
ended.
Warning!
Never set the voltage too high. In the case of lithium batteries, the battery may catch
fire or explode. Follow the battery manufacturer's instructions.
buttons (3) and (20) to save the
button until the main menu appears
If the settings are not saved at the end, all
Please refer to 'Loading battery profile

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

2267185

Inhaltsverzeichnis