- while maintaining this situation, use the toggle switch RPM +/- on the transmitting
unit. Move it to + in order to invert the semiaxis direction or to - in order to reset
the semiaxis direction.
Setting
modules with
Position 0: PWM signal frequency
(PWM) cur-
When the rotary switch S is at 0, the PWM (current) signal frequency can be adjusted.
rent outputs
Normally this value shouldn't be modified. If necessary, proceed as follows:
- take one joystick out of the rest position
- use the toggle switch RPM +/- to modify the value while maintaining same joystick
position.
Position 1: minimum and maximum Z2-Z7
When the rotary switch S is at 1, it is possible to regulate the maximum and minimum
voltage (or current) values of the two semiaxes of a joystick. Proceed as follows:
1. To set the maximum value, take the joystick to the maximum range of the semiaxis
to be calibrated. Use the toggle switch RPM +/- to modify the value while maintaining
same joystick position.
2. To set the minimum value, take the joystick just out of the rest position of the se-
miaxis to be calibrated. Use the toggle switch RPM +/- to modify the value while
maintaining same joystick position.
Positions 3 and 4: minimum and maximum Z8 and Z9
When the rotary switch S is at 3 and 4, it is possible to regulate the maximum and
minimum voltage values of auxiliary outputs Z8 and Z9 respectively. Proceed as fol-
lows:
1. To set the maximum value, turn the Z8 (or Z9) command knob (present in the
transmitting unit) fully clockwise. Use the toggle switch RPM +/- to modify the value
while maintaining same knob position.
2. To set the minimum value, turn the Z8 (or Z9) command knob (present in the tran-
smitting unit) fully counterclockwise. Use the toggle switch RPM +/- to modify the va-
lue while maintaining same knob position.
Saving the
setting
8. Switch off the transmitting unit to save the settings.
9. Disconnect power from the receiving unit.
10. Extract the K1 settings key.
11. Close the receiving unit and power it.
12

RADIO FREQUENCIES

The radio frequencies that are programmed in the radio remote control belong to the
frequencies permitted by the European norms that are permitted when the device is
put onto the market.
A radio remote control can be programmed in AUTOMATIC SCAN or MANUAL SELEC-
TION.
Automatic
scan
A radio remote control is normally programmed by the producer in the following man-
ner: it can therefore operate in any of the available frequencies. In cases of interfe-
rence or conflict with other systems, the working frequency can be moved (see
paragraph "Frequency change") without having to touch the inside of either the tran-
smitting or the receiving units.
Manual
selection
Using the radio remote control in the manual selection mode makes it possible to
work at a specific frequency. To set this frequency, you must set the dip switches
present in the transmitting and receiving modules.
Check for possible user conutry limitations in "Limitations & Autho-
risations" enclosure.
Only contact Autec authorised personnel if the working radio fre-
quency has to be set in this manner.