Proportional Output Setting Procedure (Remote Set Up) - Autec C26 PRO Serie Handbuch

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 31
Internal
signalling
The leds that are present show when a relay has activated: when a led switches on,
this means that the relative command relay given in the following drawing (also pre-
sent inside the receiving lid cover) has been activated:
SAFETY
The radio remote control is equipped with a safety function called SAFETY which pro-
tects the system from involuntary movements caused by possible radio remote con-
trol faults.
This function constantly controls the rest position (neutral) of the movement actua-
tors in the transmitting unit and is available on the receiving unit SAFETY relay ou-
tput.
FLOW
Activating a movement command also activates the FLOW function: this commands
the solenoid valve which puts the oil in the hydraulic circuit of the main distributor
under pressure.
T.S.
T.S. (TIMED STOP) is the command that switches off the machine diesel motor: it re-
mains active for 10 seconds after the STOP pushbutton has been pressed.
Fuse
The three fuses inside the receiving unit have the following characteristics:
Fuse
11
PROPORTIONAL OUTPUT SETTING PROCEDURE (REMOTE
SET UP)
Information
about RI97-08
The proportional outputs of RI97-08____ module are programmed at the values gi-
module
ven on the relevant technical data sheet. The identification number of the technical
data sheet for each radio remote control is written on data memory (K2))
Function
F1
POWER SUPPLY circuit guard
F2
STOP circuit guard
F3
SAFETY circuit guard
The proportional outputs must only be set by qualified and trained
personnel who respect all the warnings given in chapters 4, 5, 6 and
7.
C3
C1
C2
S
C5
C4
K1
L
P
C1
connector for the proportional outputs
C2
connector for the auxiliar proportional outputs
C3
connector for the power supply
C4
connector for the calibration key
C5
connector for the coonection to the bus board
L
green led
K1
calibration key
K2
data memory
P
initial values reset push button
S
rotaty switch
K2
- 26 -
Technical Data
4A (32Vdc, autofuse)
10A (32Vdc, autofuse)
10A (32Vdc, autofuse)
LIPROMU2