To reset the initial proportional output values (i.e. those given in the technical data
sheet), with calibration key K1 inserted, just keep reset button P pressed until the
green led L stops flashing and remains lit.
To keep the same settings in case of module replacement, move the K2 memory from
the old module to the new one.
Preparation
for setting 1. Make sure that the transmitting unit is switched off.
2. Disconnect the power from the receiving unit.
3. Open the receiving unit and insert the K1 settings key into the C4 connector.
4. Power the receiving unit. ATTENTION: From this moment onwards do not touch
the receiving unit until setting up has been completed (otherwise you risk losing the
settings that have already been set)
5. Turn the transmitting unit ignition key to "I" and press the START pushbutton.
6. Turn the starting key to the "
Setting
7. Select the parameters to be set using the rotary switch S, which can be found on
the RI97-08 module, and the RPM+/- selector, which is present on the transmitting
unit (+ increases the value being set, - decreases it).
Setting mo-
dules with
Position 1: minimum and maximum Z2-Z7
voltage output
When the rotary switch S is at 1, it is possible to regulate the maximum and minimum
voltage values of the two semiaxes of a joystick. Proceed as follows:
1. To set the maximum value, take the joystick to the maximum range of the semiaxis
to be calibrated. Use the toggle switch RPM +/- to modify the value while maintaining
same joystick position.
2. To set the minimum value, take the joystick just out of the rest position of the se-
miaxis to be calibrated. Use the toggle switch RPM +/- to modify the value while
maintaining same joystick position.
Position 2: joystick standstill position voltage
When the rotary switch S is at 2 the voltage value which corresponds to the mecha-
nical rest position of the joystick can be regulated. Normally, this value shouldn't be
modified. Proceed as follows:
- take any joystick out of the rest position
- use the toggle switch RPM +/- to modify the value while maintaining same joystick
position.
Positions 3 e 4: minimum and maximum Z8 and Z9
When the rotary switch S is at 3 and 4, it is possible to regulate the maximum and
minimum voltage values of auxiliary outputs Z8 and Z9 respectively. Proceed as fol-
lows:
1. To set the maximum value, turn the Z8 (or Z9) command knob (present in the
transmitting unit) fully clockwise. Use the toggle switch RPM +/- to modify the value
while maintaining same knob position.
2. To set the minimum value, turn the Z8 (or Z9) command knob (present in the tran-
smitting unit) fully counterclockwise. Use the toggle switch RPM +/- to modify the va-
lue while maintaining same knob position.
Position 5: semi-axis inversion
Semiaxis direction is inverted when the rotary switch S is at 5. Proceed as follows:
- take the joystick of the axis to be inverted out of the rest position
LIPROMU2
Never leave the K1 calibration key inserted during radio remote
control use. The key is only needed during the calibration phase
and, when inserted, only one proportional command can be activa-
ted at a time.
In modules with voltaged outputs it is possible to set positions 1, 2,
3, 4 and 5. In modules with current outputs (PWM) it is possible to
set positions 0, 1, 3 and 4.
If the joystick is moved out of its rest position during setting, the
horn/alarm sounds for 0.5 seconds, indicating that you are in the
minimum setting area.
Each single position of the speed selector present on the transmit-
ting unit must be set.
- 27 -
" position (REMOTE SET UP).
English