IndraDrive Drive Controllers Power Sections HCS03
4.2.2

Connection points

Symbols used to describe the connection points
Screw terminal block
Connection point
HCS03
X3
A
1)
X5
B
2)
C
3)
X6
A, B, C
Apart from the indicated connections, it is necessary to wire the
Bb contact at the control section for signaling the readiness for
operation of the drive controller (see Project Planning Manual
"Rexroth IndraDrive Drive Controllers Control Sections").
For proper function of the motor thermal management connect the motor
thermal sensor as described in the wiring diagram. Otherwise motor
overtemperature sensing is not provided by the drive.
For Rexroth motors with data memory in the motor encoder, such as MSK,
the motor overload protection level is set automatically while connecting the
motor to the drive. There is no adjustment necessary. Otherwise refer to the
Rexroth firmware documentation.
Spring terminal
Tab. 4-1:
Symbols
Thread
Max. connection cross
section
mm
(AWG)
2
16.0 (6)
M6
1×16; 1×25; 1×35; 1×50
2×25; 2×35; 2×50
2×16 with accessories
(1×6; 1×4; 1×2; 1×1
2×4; 2×2; 2×1
2×6 with accessories)
M10
1×16; 1×25; 1×35; 1×50
2×25; 2×35; 2×50
2×16 with accessories
(1×6; 1×4; 1×2; 1×1
2×4; 2×2; 2×1
2×6 with accessories)
(motor): M8
(mains): M6
1.5 (16)
R911319656_Edition 09 Bosch Rexroth AG
21/27
Instructions for use
Max. tightening torque
Nm
1.7
6.5
20
(motor): 20
(mains): 6.5
-