Little or No Mist
Generation
The flame effect
has too much
smoke.
Bluetooth Receiv-
er stops working
Remote Control
stops working
Transducer not operating correctly
Transducer is dirty
Transducer is not sitting correctly
in sump
---
Fan is obstructed or blocked
Nozzle is not on sump correctly
Nozzle is blocked
---
Flame effect setting is too high
---
Loose connection
Bluetooth range issue
Bluetooth Receiver connection is
---
loose
Remote control batteries need
replacing
Check operation of transducer
Clean sump and transducer thoroughly
Switch off product, take nozzle off sump and
ensure transducer is fitted in sump correctly
Remove air filter and clean. Ensure it is
placed back in product correctly.
Ensure Nozzle is sitting on sump correctly
Clean sump, transducer and nozzle thor-
oughly
Turn down the flame effect. Give the product
time to adjust to the new setting
Check connection to jack (Fig 12)
Check positioning of Bluetooth Receiver.
Ensure it is not encased in metal or concrete.
Check connection to jack (Fig 12)
Replace batteries with two new AAA batteries