Installing the CP 1411 in the PC/Programming Device

2.1

Important Notes

Electrostatically
discharge (ESD).
Sensitive Devices
Installing the
Never open the PC/programming device or plug in or remove modules
CP 1411
when the power supply is on.
Reading the
Before installing your module, please read the section in your
PC/programming device manual explaining how to install modules and
Manual
follow the instructions there.
Transceiver Power
The CP 1411 provides a voltage of 12 V at its AUI port to supply a
transceiver. The load on this should not exceed a continuous current of
Supply
500 mA.
Please remember that the maximum current of the 12 V power
supply must be limited to 8 A in the power supply unit of your
PC/PG.