8. Switching off
The dial gauge goes automatically into stand-by if not used for 10 minutes,
unless automatic switch-off mode has been turned off (see Chap. 4, ad-
vanced functions).
Stand-by mode can be forced by a prolonged press (> 2 sec) on
SET
>2s
In stand-by mode, the value of the origin is retained by the sensor (SIS
mode), and the instrument automatically restarts with any movement of the
measurement probe, RS command, Bluetooth
The instrument can be switched off completely for a long period of non-
use, but this will necessitate a zero reset on restart (the origin will be lost) :
- Prolonged press (>4 sec) on
SET
>4s
9. Re-initialising the instrument
The initial instrument settings can be restored at any time by a prolonged
press (>4 sec) simultaneously on
is displayed.
10. Personalising the instrument
Access to the functions of your instrument can be personalised, for more
information see manufacturer's website (requires you to connect your
instrument via Power RS / USB cable, or Bluetooth
Possibilities :
- Enable or disable the required functions.
- Modify access to the advanced functions (direct access).
12
request or press on button.
®
:
SET
and
MODE
SET
SET
until the message rESEt
).
®
: